Manual
52
4.12.1.6 Predefined Voltage Levels
This command is used to set the pulse voltage levels to predefined values. Four predefined values are
available as follows:
CMOS: High level 5V; Low level 0V
TTL: High level 2.4V; Low level 0.4V
ECL: High level –0.8V; Low level –1.8V
USER: User-defined levels, as set using the PHIGH and PLOW commands
COMMAND TYPE: Setting only
SETTING
Syntax: [:SOURce]:VOLTage[:LEVel][:IMMediate]:PREDefined<ws><option>
Arguments:
Type: Character
Options: CMOS, TTL, ECL, USER
Examples: :VOLT:PRED ECL
4.12.1.7 High Voltage Limit
This command is used to set the high limit of the pulse.
COMMAND TYPE: Setting or Query
SETTING
Syntax: [:SOURce]:VOLTage:LIMit:HIGH<ws><high limit>[units]
Arguments:
Type: NRf
Units: MV, V (default)
Range: -9.5V to +10V
Rounding: To 10mV
Examples: :VOLT:LIM:HIGH 4V
QUERY
Syntax: [:SOURce]:VOLTage:LIMit:HIGH?
Examples: :VOLT:LIM:HIGH?
Response: NRf
CONSIDERATIONS:
The high limit cannot be set to less than the high level.
4.12.1.8 Low Voltage Limit
This command is used to set the low limit of the pulse.
COMMAND TYPE: Setting or Query
SETTING
Syntax: [:SOURce]:VOLTage:LIMit:LOW<ws><low limit>[units]
Arguments:
Type: NRf
Units: MV, V (default)
Range: –10V to +9.5V
Rounding: To 10mV
Examples: VOLT:LIM:LOW 4V