User Manual
84 
[:NUMber] <NR1 | ?> 
Set or return step number 
:ACTion <OFF/0, ON/1, 
    NAC/2, END/3 
    | ?> 
Set or return step n action state 
:CURRent <NRf | ?> 
Set or return step n current value 
:ONTime <NRf | ?> 
Set or return step n time value 
:VOLTage <NRf | ?> 
Set or return step n voltage value 
:TOTAl? 
Return program total n step numbers 
PROTection 
Protection subsystem 
[:STATe] ? 
Return the protected state, 0=no 
protection happened, 1=OVP, 2=OCP, 
3=OPP, 4=CV to CC and 5=CC to CV 
:CCCV <Bool | ?> 
Set or return CC to CV protection 
switch 
:CLEar 
Reset latched protection 
:CVCC <Bool | ?> 
Set or return CV to CC protection 
switch 
:OCP 
[:STATe] <Bool | ?> 
Set or return over-current protection 
switch 
:LEVel <NRf | ?> 
Set or return over-current protection 
level 
:OPP 
[:STATe] <Bool | ?> 
Set or return over-power protection 
switch 
:LEVel <NRf | ?> 
Set or return over-power protection 
level 
:OVP 
[:STATe] <Bool | ?> 
Set or return over-voltage protection 
switch 
:LEVel <NRf | ?> 
Set or return over-voltage protection 