User Manual
46 
Power OK Signal 
Pin 16 is used to indicate whether a fault condition is present in the 
power supply. Normally this pin will output a logic high (5V). When a 
fault occurs, this pin will output a logic low (0V). 
Fault conditions are defined as follows: 
1. Overvoltage protection 
2. Overcurrent protection 
3. Overpower protection 
4. CV to CC protection 
5. CC to CV protection 
6. Overtemperature protection 
7. AC line failure 
8. Enable signal 
9. Shutoff signal 
10. Remote failure 
11. Output off 
Voltage Program 
This function is able to program the voltage output by connecting an 
external DC voltage (voltage mode) or an external resistor (resistor 
mode) to Pin 9. For this function to be enabled, the output control must 
be in analog mode. The external voltage range or resistor range used to 
control the full scale of the output voltage can be selected between 0-5 
V / 0-5 kΩ and 0-10 V / 0-10 kΩ range. Follow the steps below to 
configure the voltage program. 
1.  Press the   button and press the   button one time until 
CONFIG is blinking and press  . 