User Manual
65 
8.  Press   to select NEXT PROG parameter and use the rotary 
knob to select a value of NONE or a value of 1-9. As described 
previously, the user has the ability to queue another program 
once the current program is finished. By default, NONE is placed 
as the parameter value. 
9.  Press   to complete the program configuration. 
10. Make sure the program is turned ON and press   to exit the 
program settings. 
11. Once the output state is enabled, by pressing  , the program 
will automatically execute. The following will be displayed when 
the program is executing: 
When program mode is running, an * indicator on the display will flash 
to indicate the program is running. The current program (PRG: p), step 
(S: sss) and repeat number (R: xx / yy) will also show on the display. 
Where p is the program number, sss is the step number, xx is the 
present repeated number and yy is the total repeat number. For 
example, if the xx is 01 and yy is 03, this means that there are three 
repeats of this program and it is now running the first repeat. 
3.9  Timer Function 
The timer function is a countdown clock, which allows the user to setup 
how long the output will be enabled when it is initially turned ON. 