User manual
47 
2.  Press   button three times until EXTCTRL is blinking and 
press  .  
3.  Press   button one time to select VOLTAGE and press  .  
4.  Use the rotary knob to select EXT-V (external voltage) or EXT-R 
(external resistance) option and press  . To have front panel 
control, select FRONT. 
5.  Use the     keys to select PROG RNG (program range) 
and press  . 
6.  Now use the rotary knob to select between 10V/10K or 5V/5K 
and press  . 
7.  Press   several times to exit the menu setting. 
Voltage Mode 
Under voltage mode, the user may control the full scale output voltage 
value through Pin 9, by inputting a voltage level of 0-5 V (0-5 V / 0-5 kΩ 
mode) or 0-10 V (0-10 V / 0-10 kΩ mode) as shown below.  
Figure 3.4 – Analog Voltage Programming Diagram (Voltage Mode) 
Resistor Mode 
Under resistor mode, the user may control the full scale voltage output 
0 – 5 V 
or 
0 – 10 V 