User manual
54 
Figure 3.10 – Parallel Connection Diagram 
After wiring is complete, configure one of the supplies as the Master 
and the other three as Slave A, B, and C. After one of the supplies is 
configured to be the Master, it will start searching for all Slaves that are 
connected to the Master. To operate correctly, the user must set up the 
Slaves before the Master. Follow the steps below to set a supply to 
master or slave mode.  
1.  Press the   button and press the   button one time until 
CONFIG is blinking and press  . 