User manual
59 
the I-V profile. 
b)  Manually generate the I-V curve by creating a user-defined table 
of points in the SAS software. Up to 1024 I-V points can be 
downloaded to the PVS supply’s non-volatile memory. 
Once one of these I-V curves has been selected and set from the front 
panel, the power supply will operate in PV mode and output a voltage 
and current value according to the active I-V profile and load conditions. 
Different points on the I-V curve will be output in 1 ms intervals to test 
the inverter’s MPPT efficiency. To create a user-defined table of I-V 
points and simulate a change in irradiance conditions (e.g. cloudy or 
rainy day), the PV supply must be controlled by the SAS software. The 
SAS software also monitors and logs real-time voltage, current, and 
power as well as real-time and average MPPT efficiency to validate the 
inverter’s MPPT algorithm. 
To configure and set the PVS power supply to PV mode from the front 
panel, follow the steps below: 
1.  Press the   button and press the   button three times 
until PV SIM is blinking, then press  . The following display 
will be shown: 
2.  Use the     keys to move the cursor to the ON/OFF field 
and use the rotary knob to select ON or OFF. ON means the PVS 
supply is set to PV mode. 