INSTRUCTION MANUAL El Manual de la Instrucción MODEL 1735A MODELO 1735A Manual de Instruccion 0-30V, 0-3A DC POWER SUPPLY With Dual 4-Digit LED Displays Fuente de poder DC Con doble LED indicador
TEST INSTRUMENT SAFETY WARNING Normal use of test equipment exposes you to a certain amount of danger from electrical shock because testing must sometimes be performed where exposed high voltage is present. An electrical shock causing 10 milliamps of current to pass through the heart will stop most human heartbeats. Voltage as low as 35 volts dc or ac rms should be considered dangerous and hazardous since it can produce a lethal current under certain conditions. Higher voltages are even more dangerous.
Instruction Manual for Model 1735A 0-30 V, 0-3 A DC POWER SUPPLY With Dual LED Display 22820 Savi Ranch Parkway Yorba Linda, CA 92887 www.bkprecision.
TABLE OF CONTENTS Page Page TEST INSTRUMENT SAFETY ----------------inside front cover APPLICATIONS ----------------------------------------------------21 General--------------------------------------------------------------21 Electronics Servicing --------------------------------------------21 Electronics Manufacturing--------------------------------------21 Electronics Design Lab ------------------------------------------22 Electronics Education --------------------------------------------22 Battery Cha
INTRODUCTION The B+K Precision Model 1735A DC Power Supply is a high quality, general purpose dc power source. It provides 0-30 volts dc output, adjustable with both coarse and fine voltage controls for precise settability. The current output is 0-3 amps, adjustable with both coarse and fine current controls. Two large LED meters continuously monitor the output voltage and current. The VOLTAGE meter is green, while the CURRENT meter is red. Current limits are adjustable from 5% to 100% of maximum.
FEATURES LED INDICATORS 0-30 VOLTS Act as pilot light and identify mode of operation and metering. Continuously variable over 0-to-30 volt range with coarse and fine controls. PRE- REGULATOR 0-3 AMPS Limits internal dissipation for higher reliability. 0-to-3 amp current rated for continuous duty at full output current. Coarse and fine current adjust controls. ISOLATED OUTPUT LABORATORY QUALITY Either polarity may be floated or grounded. Excellent regulation, low ripple.
SPECIFICATIONS OUTPUT VOLTAGE: adjustment. 0 to 30VDC, coarse and fine Line (108-132 V): Load 0.2% + 3mA 0.2% + 3mA OUTPUT CURRENT: 0 to 3A, coarse and fine adjustment. Current Ripple: 3mA typical. CONSTANT VOLTAGE OPERATION METERING Voltage Regulation Line (108-132 V): Load (no load to full load): 0.01% + 3mV. 0.01% + 3mV. Voltmeter Range: Accuracy: Recovery Time: 100 µs typical. Ripple Voltage Peak-to-Peak: RMS: 2mV, typical 1mV. 4 digit Green LED Display 0 to 99.99 V. (0.5% + 9 digits)*.
SPECIFICATIONS TEMPERATURE RANGE Operation: Storage: 0° to +40° C, 75% R.H. -15° to +70° C, 85% R.H. WEIGHT: DIMENSIONS (HxWxD): 6.2 x 5.5 x 12.5" 10.5 lb. ACCESSORIES SUPPLIED: Instruction Manual, Spare Fuse NOTE: Specifications and information are subject to change without notice. Please visit www.bkprecision.com for the most current product information.
CONTROLS AND INDICATORS INDICATORS CURRENT CONTROL Either the “CC” or “CV” and the LED indicators will be lit whenever the unit is operating, thus serving as a pilot light. The unit automatically changes from CV to CC operation when the preset current limit is reached. 1. C.C. (Constant Current) Indicator. Red LED lights in constant current mode. Unit regulates output current at value set by CURRENT controls. 2. C.V. (Constant Voltage ) Indicator. Green LED lights in constant voltage mode.
CONTROLS AND INDICATORS REAR PANEL CONTROLS 13. Fuse. 14. Power Cord. 15. 110/220 Line Voltage Conversion Switch. Figure 1. Front Panel Controls and Indicators. Figure 2.
OPERATING INSTRUCTIONS SAFETY PRECAUTIONS Use only a polarized 3- wire ac outlet. This assures that the power supply chassis, case, and ground terminal are connected to a good earth ground and reduces danger from electrical shock. There is little danger of electrical shock from the power supply output, which produces a maximum of 30 volts dc. However, there may be great danger of electrical shock if the power supply output is connected to an external high voltage.
OPERATING INSTRUCTIONS Equipment Being Powered Equipment Being Powered Strap A. Strap B. Grounded, common with negative polarity Grounded, common with positive polarity Figure 3 (A and B). Grounding Possibilities.
OPERATING INSTRUCTIONS No Strap C. Equipment Being Powered Equipment Being Powered No Strap D. No ground reference Grounded, not common with Negative or positive polarity. Figure 3 (C and D). Grounding Possibilities.
OPERATING INSTRUCTIONS c. If an earth ground reference is not required, the configuration of Fig. 3C may be used. The scheme in Fig. 3C should also be used where it is not known whether the chassis is common with either the positive or negative polarity. d. If the chassis or common of the equipment being powered is separate from both the positive and negative polarity power inputs, use the connection shown in Fig. 3D. 6. Observe proper polar ity.
OPERATING INSTRUCTIONS 5. Increase the VOLTAGE setting until the Voltage LED display reads the desired value. The FINE control permits easier setting to a specific value. 6. Note the load current on the Current LED display. 7. If the load current exceeds the preset current limit, the CV indicator will go off and the CC indicator will light. In this case, the power supply automatically switches to the constant current mode, and further rotation of the VOLTAGE control will not increase the output voltage.
OPERATING INSTRUCTIONS TYPICAL CONSTANT CURRENT OPERATION 1. Before connecting the device to be powered to the power supply, determine the maximum safe voltage to be applied, and set the VOLTAGE controls to obtain that voltage reading on the Voltage LED display. 2. Determine the desired constant current value. 3. Set the Coarse and Fine CURRENT control to minimum (fully counterclockwise). 4. Turn off the power supply and connect it to the device to be powered. 5. Turn on the power supply.
OPERATING INSTRUCTIONS CONSTANT VOLTAGE/CONSTANT CURRENT CHARACTERISTIC The working characteristic of this power supply is called a constant voltage/constant current automatic crossover type. This permits continuous transition from constant current to constant voltage modes in response to the load change. The intersection of constant voltage and constant current modes is called the crossover point. Fig. 7 shows the relationship between this crossover point and the load.
OPERATING INSTRUCTIONS Output voltage equals sum of both displays “in voltage metering mode” Output current equals value on either ammeter (both read identical) Load Figure 8. Connecting Two Power Supplies in Series.
OPERATING INSTRUCTIONS Adjust both power supplies to same voltage Output current equals sum of both displays Use load equalizing resisters 0.1Ω 1W 0.1Ω 1W Load Figure 9. Connecting Two Power Supplies in Parallel.
OPERATING INSTRUCTIONS CONNECTING TWO POWER SUPPLIES IN PARALLEL If the current equalizing resistors are not well matched, it is preferable that the voltages be slightly unbalanced to achieve current balance. Be sure that the supplies are adequately balanced so that both remain in the CV mode. Two power supplies may be connected in parallel to double the maximum load current.
APPLICATIONS GENERAL The Model 1735A power supply has a very wide variety of applications in electrical and electronics servicing, engineering laboratories, manu facturing and testing facilities, schools, and home hobbying. The power supply output is fully adjustable from 0 to 30 volts and 0 to 3 amps. This flexibility makes them suitable for most applications requiring a dc power source. The equipment being tested may contain its own power supply and operate from ac power.
APPLICATION ELECTRONICS DESIGN LAB BATTERY CHARGING The technician or engineer working in an engineering laboratory requires a dc power supply to power breadboard and prototype circuits. This power supply is ideal because it monitors output current, output voltage, limits current to protect the circuit, is adjustable over a wide range, and has excellent regulation and very low ripple.
MAINTENANCE WARNING LINE VOLTAGE UNITS The following instructions are for use by qualified personnel only. To avoid electrical shock, do not perform any servicing other than contained in the operating instructions unless you are qualified to do so. FUSE REPLACEMENT If the fuse blows, the CV or CC indicators will not light and the power supply will not operate. The fuse should not normally open unless a problem has developed in the unit.
MAINTENANCE 1735A CALIBRATION If readjustment is required, use the following procedure. Locations of the adjustments are shown in Fig. 11. 1. Set the front panel controls of the Model 1735A as follows: Coarse and Fine VOLTAGE controls fully clockwise. Coarse and Fine CURRENT controls fully clockwise. Power switch to On. 2. Connect the Multimeter to measure the voltage at pin 7 of IC2 with respect to the front panel red (+) output jack. Adjust R21 for -5.00 volts on the Multimeter. 3.
MAINTENANCE Figure 11. Location of Adjustments.
NOTES 26
Service Information Warranty Service: Please return the product in the original packaging with proof of purchase to the address below. Clearly state in writing the performance problem and return any leads, probes, connectors and accessories that you are using with the device. Non-Warranty Service: Return the product in the original packaging to the address below. Clearly state in writing the performance problem and return any leads, probes, connectors and accessories that you are using with the device.
Limited Two-Year Warranty B&K Precision Corp. warrants to the original purchaser that its products and the component parts thereof, will be free from defects in workmanship and materials for a period of two years from date of purchase. B&K Precision Corp. will, without charge, repair or replace, at its option, defective product or component parts. Returned product must be accompanied by proof of the purchase date in the form of a sales receipt. To obtain warranty coverage in the U.S.A.
TEST INSTRUMENT SAFETY (continued from inside front cover) 4. If possible, familiarize yourself with the equipment being tested and the location of its high voltage points. However, remember that high voltage may appear at unexpected points in defective equipment. 5. Use an insulated floor material or a large, insulated floor mat to stand on, and an insulated work surface on which to place equipment; and make certain such surfaces are not damp or wet. 6.
SEGURIDAD DE EL INSTRUMENTO DE PRUEBA PRECAUCIONES Uso normal de probado de prueba te espose a cierta cantidad de peligro por un choque eléctrico porque revisiones son algunas veces hechas donde hay alto voltaje descubierto. Un choque eléctrico que cause 10 milliamps pasar a través del corazón pararía la mayoría de los corazones humanos. Voltaje tan bajo hasta 30 voltios dc ou ac rms podría ser considerado peligroso porque puede producir una corriente letal bajo ciertas condiciones.
Manual de instrucciones Modelo 1735A Fuente de poder DC Con doble LED indicador 31
TABLA DE CONTENDIDO SEGURIDAD DE EQUIPO DE PRUEBA Conectando dos fuentes de poder en paralelo ..............48 INTRODUCCION..............................................................33 APLICACIONES ..............................................................49 CARACTERISTICAS.......................................................34 General................................................................................49 ESPECIFICACIONES.......................................................
INTRODUCCION El B & K Precision Modelo 1735 CD Fuente de Poder es de una alta calidad, propósito general cd fuente de poder. Provee 0 –30 voltios cd salida, ajustable con ambos grueso y fino controles de voltaje para precisos ajustes. La salida de corriente es 0-3 amperios, ajustable grueso y fino controles de corriente. Dos grandes LED medidores continuamente observan el voltaje y corriente de salida. El medidor de VOLTAJE si verde, cuando el medidor de corriente es rojo.
CARACTERÍSTICAS 0-30 VOTIOS LED INDICADOVES Continuamente variable sobre 0 a 30 voltios rango con grueso y Actúa como piloto y identifica el modo de operación y medida fino controles PRE-REGULADOR 0-3 AMPERIOS Limita disipación interna para mas alta confiabilidad 0 a 3 amps corriente probada para continuo servido al la completa S ALIDA AISLADA salida de corriente .
ESPECIFICACIONES VOLTAJE DE SALIDA: 0 a 30VDC grueso y fino ajuste MIDIEDO Voltímetro: Rango: Precisión: Amperímetro Rango: Precisión: CORRIENTE DE SALIDA: 0 a 3A grueso y fino ajuste OPERACIÓN DE CONSTANTE VOLTAJE Regulación de voltaje Línea (108-132V): 0.01%+3mv Carga (no carga a carga completa):0.
ESPECIFICACIONES RANGO DE TEMPERATURA Operación: 0° a +40°C, 75%R.H Almacenamiento: -15° a +70°C, 85% R,H DIMENSIONES (AxAxP): 6.2x5.5x12.5” PESO: 10.5 LB ACCESORIOS INCLUIDOS : Fusible extra, Manual de instrucciones NOTA: Las especificaciones y la información están conforme a cambio sin el aviso de B&K Precision Corp. Por favor visite www.bkprecision.com para las especificaciones más corriente y información de nuestros productos.
CONTROLES Y INDICADORES INDICADORES CONTROLES DE VOLTAJE 5. Grueso Control (Control grueso) . Ajustes gruesos de el voltaje de salida. Lea valor en la GREEN(VERDE) LED pantalla. 6. Fine Control (control fino). Ajuste fino de salida de voltaje. Lea el valor en GREEN (verde) LED pantalla. CONTROLES DE CORRIENTE 7. Grueso CURRENT(corriente) control. Ajuste el limite de corriente en constante voltaje modo. Ajusta constante valor de corriente en el constante corriente modo.
CONTROLES E INDICADORES CONTROLES DEL PANEL TRASERO 13. Fusible 14. Cordón de poder Figura 1.Controles e indicadores de el panel delantero Figura 2.
INSTRUCCIONES DE OPERACION PRECAUCIONES DE SEGURIDAD Use solo a polarizado 3-conductores ca enchufe. Esto asegure que la fuente de poder chasis, caja, y la terminal de tierra son conectada a una buena tierra y reduce el peligro de un choque eléctrico. Hay un pequeño peligro de choque eléctrico dela salida de la fuente de poder, cual produce un máximo de 30 voltios cd. Pero, puede haber un gran peligro de choque eléctrico si la salida de la fuente de poder es conectada a un extremado alto voltaje.
INSTRUCCIONES DE OPERACIÓN Equipo encendido Equipo encendido Corto A. Corto Tierra,comun con Polaridad negativas B. Tierra,comun con polaridad positiva Figura A y B .
INSTRUCCIONES DE OPERACIÓN Sin Corto C. No referencia a tierra Equipo encendido Sin Corto D.
INSTRUCCIONES DE OPERACIÓN c. Si la referencia de tierra no es requerida, la configuración de Fig. 3C puede ser usada. El diagrama in Fig.3C debería también ser usado donde no es conocido si el chasis es común con la polaridad positiva o negativa. d. el chasis o común de el equipo encendido es separado de ambas polaridades negativa y positiva entradas de poder, use la conexión en Fig. 3D. 5. Observe polaridad apropiada.
INSTRUCCIONES DE OPERACIÓN 5. xAumente la posición de el VOLTAJE hasta que la Voltaje LED pantalla lea el valor deseado. El control FINO permite mas fácil colocación a un valor especifico. 6. Note la carga de la corriente en la Corriente LED pantalla. 7. Si la carga de corriente excede el limite de corriente establecido, el CV indicador se apagara y el indicador de CC prendera.
OPERACION TIPICA DE CORRIENTE CONSTANTE 1. Antes de conectar el dispositivo que va ha ser encendido por la fuente de poder, determine el voltaje máximo seguro que va ha ser aplicado, y coloque los controles de VOLTAJE para obtener esa lectura de voltaje en la Voltaje LED pantalla. 2. Determine el valor deseado de corriente constante. 3. Ponga el Grueso y Fino conteo de CORRIENTE al mínimo (completamente en contra de la dirección de las anejillas del reloj) 4.
VOLTAJE CONSTANTE/ CORRIENTE CONSTANTE CARACTERISTICAS Rango de corriente constante La característica de trabajo de esta fuente de poder es llamada un constante voltaje/ constante corriente automático cruce tipo. Esto permite continua transición de constante corriente a constante voltaje modo en respuesta al cambio de carga. La intersección de constante voltaje y constante corriente modos es llamada él punte de cruce. Fig. 7 muestra la relación entre punto de cruce y la carga.
Voltaje de salida es igual a la suma de ambas pantallas Lea la corriente de cualquier Los dos lean idénticamente Carga Figura 8 .
Ajuste ambas fuentes de poder a el mismo voltaje salida de corriente es igual a la suma de las dos pantallas Uso de resistores igualadores 0.1? 1W 0.1? 1W Carga Figura 9.
CONECTANDO DOS FUENTES DE PODER EN PARALELO Dos fuentes de poder pueden ser conectadas en paralelo para doblar la corriente máxima de corriente. En esta configuración las dos fuentes proveerán dos 0-30 voltios salida hasta 6 amps (mas grueso de sondas es recomendable). Resistor igualador de corriente debe de ser usados como se muestra en la Fig. 9. Pero, la característica protectiva de la limitación de corriente prevendrá daño si la corriente es temporalmente disbalanceada en el arreglo. cada fuente.
APLICACIONES aislada, como el modelo 1735A. El equipo bajo prueba puede contener su propio fuente de poder y operar de ca energía. Un voltaje cd puede estar ya presente en el circuito. Una polaridad de la salida de la fuente de poder es flotada a un punto apropiado en el circuito, como el emisor de un transistor. La otra polaridad de la salida de la fuente de poder es entonces aplicada a otro punto en el circuito , tal como la base de el transistor.
. APLICACIONES LABORATORIO DE DISENO ELECTRONICO El técnico o el ingeniero trabajando en un laboratorio de ingeniería recrié de una fuente de energía cd para prender tableros y circuitos. Esta fuente de poder es ideal porque ve la corriente de salida, el volare de salida, limita la corriente para proteger el circuito, y es ajustable sobre un ancho rango, además tiene excelente regulación y muy baja ondulación.
MANTENIMIENTO PRECAUCION Las siguientes instrucciones son solo para el uso de personal calificado. Para evitar choque eléctrico, no haga ningún servicio otro que el contenido en las instrucciones de operación al menos que este calificado para hacerlo. 1. 2. REMPLAZO DE FUSIBLE Si el fusible se quema, la CV,CC o LED medidores indicadores se encenderán y la fuente de energía no funcionara. El fusible no debe de estar normalmente abierto al menos que un problema se haya desarrollado en la unidad.
1735A CALIBRACION Si ajustes son requeridos, use el siguiente procedimiento. Lugares de ajuste son mostrados en Fig. 11. 1. Ponga el panel delantero de controles de el Modelo 1735 como sigue: 6. 7. Grueso y Fino VOLTAJE controles completamente en la dirección de la anejillas del reloj Grueso y Fino CORRIENTE controles completamente en la dirección de las manejillad del reloj Switch de poder en encendido 2.
INFORMACION DE SERVICIO Servicio de Garantía: Por favor regrese el producto en el empaquetado original con prueba de la fecha de la compra a la dirección debajo. Indique claramente el problema en escritura, incluya todos los accesorios que se estan usado con el equipo. Servicio de No Garantía: Por favor regrese el producto en el empaquetado original con prueba de la fecha de la compra a la dirección debajo.
DOS-ANOS DE GARANTIA LIMITADA B&K Precision Corp. Autorizaciones al comprador original que su productos y componentes serán libre de defectos por el periodo de dos anos desde el día en que se compro. B&K Precision Corp. sin carga, repararemos o sustituir, a nuestra opción, producto defectivo o componentes. Producto devuelto tiene que ser acompañado con prueba de la fecha del la compra en la forma de un recibo de las ventas. Para obtener cobertura en los EE.UU.
SEGURIDAD DE EL EQUIPO DE PRUEBA (Continua de adentro de la pasta de enfrente) Si es posible, familiarícese con el equipo que va ha ser revisado y el lugar de los puntos de alto voltaje. Pero, recure que alto voltaje puede aparecer en puntos inesperados en equipo defectivo 5. Use un piso de material insuflado o un largo, insuflado tapete para parase en el, y una superficie de trabajo insuflada el la cual pueda poner el equipo; y asegurese que estas superficies no estén húmedas o mojadas. 6.
Declaration of CE Conformity according to EEC directives and NF EN 45014 norm Responsible Party Alternate Manufacturing Site Manufacturer’s Name: B&K Precision Corporation B&K Taiwan 0574 Manufacture’s Address: 22820 Savi Ranch Pkwy.
22820 Savi Ranch Parkway Yorba Linda, CA 92887 www.bkprecision.com © 2005 B&K Precision Corp.