Operating instructions

OI: BK MIKRO LIN.B System Components
Rev. 2.02 dated 31.05.2007 Page 15 of 30
2.2.2 Accessories
BK MIKRO LIN.B, all scanners !
Fig. 2-10: Scanners – Accessories
2.2.3 Scanning Wand
Stop position
Stop position = Zero position of the wand
Stop position
Internal backstop !
Fig. 2-11: Stop position of the wand
Note:
Do not push the wand back to its internal backstop (the real limit position)
by hand.
This damages the gear!
Initial position
The tip of the wand is to be positioned at random between the object to be monitored and the
internal backstop of the wand.
After supply voltage has been applied, and at the end of "Teach-in" or "Start" cycles the wand will
move into its stop position in any case.
Scanning range
Any scanning range between stop position and maximum stroke can be used.
Exchange the scanning tip
The tip can easily be removed from the wand (thread M3x6) and exchanged by a
project-specific variant.