Operating instructions

OI: BK MIKRO LIN.B Cycle Times
Rev. 2.02 dated 31.05.2007 Page 23 of 30
5 Cycle Times
Scanning times
The following times designate the moment of the output of results after a scanning process.
They result with minimum tolerance.
Stroke "Teach-in" "Teach-in" "Start"
1)
"Start"
1)
Intensity low
Home O.K.
Intensity high
Home O.K.
Intensity
2)
Home O.K.
Intensity
2)
Obj. O.K.
3)
10 mm 720 ms 410 ms 280 ms 170 ms
20 mm 1210 ms 670 ms 430 ms 270 ms
40 mm 2210 ms 1170 ms 740 ms 470 ms
90 mm 4700 ms 2440 ms 1510 ms 960 ms
Note:
1)
For a "Start" cycle the values will be increased by a greater range of
tolerance.
2)
For a "Start" cycle the setting of "Scanning intensity" is not decisive,
because the monitoring range is small in comparison with the entire
distance of moving (with minimum tolerance).
3)
"O.K. at object " only possible for "Multi".
This time corresponds to the time for indication of a fault message (K.O.)