Operating instructions

Status Indication OI: BK MIKRO LIN.B
Page 24 of 30 Rev. 2.02 dated 31.05.2007
6 Status Indication
6.1 Yellow LED
Fast flashing = Self-test
After power-up, the system will carry out a self-test
indicated by fast flashing of this yellow LED.
Steady illumination = Ready to operate
Following its self-test, the system is ready to operate.
The LED stops flashing and remains steady.
Slow flashing = Scanner fault
The system has detected a scanner fault:
Scanner is missing or has motor fault.
Control cable is not correctly connected, e.g. even cable break.
Outputs will be switched inactive, the unit will remain in its present state,
indicated by slow flashing of this yellow LED.
6.2 Red LED / Green LED
Steady illumination = Indication following scanning cycle
The red LED indicates a fault message.
The green LED indicates a no fault message.
Flashing = Illegal settings
A flashing red and green LED simultaneously indicates that one or more of the switches
is incorrectly set.
6.3 Error messages – Flashing red and green LED
Check the following P1 and P2 rotary switch settings to remove the error messages.
Teach mode [requires: P1 = 0, P2 = 0] Error Correction
for Learn cycle and "Start" cycle with learned position
P1 0, P2 0
P1 = 0, P2 = 0
Switch mode [requires: 0 P1 < P2 93.75]
Error Correction
Signal to "Teach" without effect, only "Start" pulse !
for object monitoring (S1 = 0) or
P2 = 0 P2 > 0
for free space monitoring (S1 = 1)
P1 = P2 P1 < P2
P1 > P2 P1 < P2