Operating instructions
OI: BK MIKRO 7 System Components
Rev. 2.01 dated 05.02.2007 Page 11 of 32
"Clockwise / Counter-clockwise" switch (CW/CCW)
Direction of rotation, i.e. direction to which scanner moves starting from stop position.
Clockwise = When rotating to the right
Scanner viewed from behind (the connection side),
looking up length of scanner.
Fig. 2-6: Definition of the rotation direction
Note:
Switch position may be changed by selection inputs S1, S2 and S3 (see table in
section "Selection inputs").
"Tolerance range" switch
Range of tolerance for "O.K." message referred to the desired position, i.e. position learned
by "Teach-in" or set by switches:
small ±3°
great ±10°
Fig. 2-7: Range of tolerance
Note:
No range of tolerance exists for scanning in one direction using switch mode.
"Scanner" switch
Selection of the scanner.
TK7A Scanner TK7A (scanner with mechanical backstop)
TK7RL Scanner TK7RL (scanner without mechanical backstop)
Stop position
Scanning wand
Scanner
Object
Desired position
g
r
e
a
t
s
m
a
l
l