Operating instructions

OI: BK MIKRO 7 System Components
Rev. 2.01 dated 05.02.2007 Page 5 of 32
2.1.2 Technical data
Housing Insulating material housing, protection class II, built-in unit
Protection type IP 20
Dimensions (W x H x D) 45 mm x 75 mm x 107.5 mm
Case mountings Sectional rail, 35 mm, to DIN EN 50022
Power supply voltage
(depending on model)
24 VDC ±20% PELV
1)
I
max
= 0.25 A
120 VAC I
max
= 0.05 A
230 VAC I
max
= 0.025 A
Power consumption 6 VA max.
Control voltage (int./ext.) 24 VDC ±20% PELV
1)
Inputs Galvanically isolated
Input current 5 mA approx.
Pulse duration 6 ms min.
Switched outputs 2 x 250 VAC / 30 VDC, 2 A max.
Making/breaking capacity 500 VA / 60 W (max.), 10 mA min. at 10 V
Operational life of relay 5 x 10
7
switching cycles
Connections Plug-in screw terminals for connecting
power supply
control inputs
selection inputs
relay outputs
Scanner socket to DIN 45322, 6 pin
Climatological conditions Classification 3K3 under EN 50178
Ambient temperature 0 ºC to +50 ºC
Storage temperature 25 ºC to +80 ºC
Fig. 2-2: Control unit Dimensions
Warning
Note:
The control unit of BK MIKRO 7 is a built-in unit (DIN EN 60950)! The system
is explicit approved for operation in closed rooms (control cabinet)!
1)
PELV = Protected Extra Low Voltage
The voltage applied must meet the requirements for an extra low function
potential with safe disconnection (PELV).
107.5
110
75
78
45
General tolerances
ISO 2768
mK