User Guide

CT
-1 Back Panel
1. CT-1 IN MASTER - 5 PIN Phoenix plug for connecting to a CT610/600/310 zone control I/O.
+12V - +12VDC power input for the CT-1
GND - Common ground for power and data
RCV - Receives RS-232 data to pass through to the RJ45 connector (RS-232 XMIT).
NC - No connection
NC - No connection
2. RS-232 XMIT (Output)- RJ45 connector used for direct RS-232 linking between a CT
Receiver and B&K A/V Home Theater preamplifier/receiver. Install a straight through
CAT-5 cable when using this connection.
Note: This connector is intended for RS-232 XMIT and Ground and is not a source of VCC power.
3. HOME THEATER SENSOR - 3 pin Phoenix plug for connecting to an IR Sensor or Keypad.
+12V - +12V power available for Home Theater IR Sensor or Keypad
IR IN - IR DATA IN from Home Theater IR Sensor or Keypad
GND - Common ground for power and data
Note: Both of the CT-1 HOME THEATER IR data inputs (IR-IN and IN), are summed together
internally.
4. CT 3 Flasher IN - Nine 1/8" mini connectors. One CT Receiver is connected by nine 1/8” mini
jack interconnects. Each interconnect should be connected corresponding with the IR output
on the CT Receiver back panel. i.e. IR OUT 1 connects to Flasher IN 1, etc. These inputs
are also used when chaining multiple CT-1’s.
5. CT 3 / Chain Out - One 1/8" mono mini connector. To be used with an IR emitter for control of a
CT Reciever. This output is a sum of IR Data from CT-1, CT-2, Home Theater and Chain IN.
This output is used when chaining CT-1s to send IR to the previous CT-1 in the chain.
6. CT 2 Flasher IN - Nine 1/8" mini connectors. One CT Receiver is connected by nine 1/8” mini
jack interconnects. Each interconnect should be connected corresponding with the IR output
on the CT Receiver back panel. i.e. IR OUT 1 connects to Flasher IN 1, etc.
CT-1 Back Panel
4
1
2
8
3
4
9
5
6
12
10
11 13
7