Data Sheet
1/8www.burkert.com
3285
can be combined with…Type3285
The direct-acting motor valve of type 3285
is used for dosing of liquids and gases in
closed or open control loops.
The valve features a stepper motor as the
actuator. The integrated electronics simpli-
es the process integration; additional ac-
tuation modules are
not necessary. The motor’s power con-
sumption to hold a specic opening position
of the valve is zero. This key feature can
reduce the energy consumption of a plant
dramatically and thus make it more ecient.
Type 3285 is available as a standard ON/
OFF or proportional valve, as a version with
integrated positioner and as a version with
integrated process controller.
•Actuator isolated from ow path
•Excellent range and fast response times
•Low power consumption
•Orice sizes 8 to 25 mm
•Versions: Standard, positioner, process controller
2/2 way Proportional Valve (motor-
driven)
MFM
Type8006
BigFlow
Type8008
MFC/MFM
Type8746
Universal controller
Type8611
Pressure transmitter
Type8311
Technical data
Materials
Body
Housing
Seals
Seat sealing
Brass or stainless steel
PC (Polycarbonate), PPS (Polyphenylene sulde)
NBR for liquids,
EPDM for liquids and special gases (e. g. ammonia,
acetylene),
FKM for neutral gases
Technical ceramics
Medium
Neutral gases, liquids
Seat leakage based on IEC/EN 60534 − 4
Shut-o class IV
Pressure range
1)
0 - 6 bar
Closure time
Ca. 4 sec.
Medium temperature
0 to + 70 °C
Ambient temperature
- 10 to + 60 °C
Power supply 24 V DC ± 10 % (max. residual ripple 10 %)
Power consumption < 1 W in holding position, Max. 12 W (depending on
motor control)
Duty cycle Up to 100 % (depending on uid and ambient tem-
perature)
Port connection G ½, G ¾, G 1, NPT ½, NPT ¾, NPT 1
Typical control data
2)
Hysteresis
Repeatability
Sensitivity
Span
< 5 %
< 1 % FS
< 1 % FS
1:100
Protection class - valve
IP50
Installation
As required, preferably with actuator upright
Status display
LED (details: see manual)
Dimensions
See drawings on page 5
Weight
~ 800 g (DN8) … 1500 g (DN25)
1)
Pressure data [bar]: Overpressure with respect to atmospheric pressure
2)
Characteristic data of control behaviour depends on process conditions
UR approval
optional
Circuit function
2-way valve for continuous
control, motor driven,
bidirectional
2 (A)
1 (P)