Brochure
Introduction CO
2
Monitor
4 Instruction 3015-9000 Rev 2
1.10 Specifications
Specification Description
Gas Detected CO
2
(R744)
Measuring Range 20 to 100,000ppm (10% vol.)
Warm-Up Time 5 minutes (300 seconds)
Detector Type Infrared, Non-Dispersive
Display Resolution 1 ppm
Accuracy ±1 ppm ±10% of reading from 0-10,000 ppm
Response Time 90% of response within 5 seconds
System Noise Less than 40dB (A) at 10 ft (3 m)
Operating Temperature 32 to 122°F (0 to 50°C)
Ambient Humidity 5 to 90% RH (non-condensing)
Altitude Limit 6,562 ft (2,000 m)
Power DC power pack, provides a minimum of 8 hours of operation
Power Consumption 15 Watts maximum
Front panel 3 indicator lights:
ON Green LED flashes during warm-up, then glows steadily during
normal operation
FAULT Yellow LED flashes when there is a system fault
ALARM Red LED flashes when the gas level is above its alarm setting
Audible Alarm Internal audible alarm programmable for any of the following conditions:
OFF, FAULT/ALARM, ALARM
Dimensions (D x L x W) 9.0 x 14.5 x 5.0 inches (229 x 368 x 127 mm)
Weight Less than 9 lbs (4 kg) including battery
Warranty 2 years from date of shipment