Combustion Gas Analyzer Operation & Maintenance

Fyrite
®
INSIGHT
Instruction 24-9460
1
Fyrite
®
INSIGHT
Instruction 24-9460
ii
1.0 INTRODUCTION
1.1 The Fyrite
®
INSIGHT
The Fyrite
®
INSIGHT is a hand-held residential and commercial grade
portable combustion an a lyz er that is designed for on-demand sampling of
light industrial combustion equipment, residential furnaces, and appli-
ances.
The Fyrite
®
INSIGHT is upgradeable from the Basic model to the Record-
ing model which includes additional features such as software compatible
for downloading data and the IrDA printer.
This manual contains information on all models of the Fyrite INSIGHT.
Please disregard any information that does not pertain to your model.
WARNINGS!
This analyzer is not intended to be used on a continuous
basis.
This analyzer is not in tend ed to be used as a safety device.
Except for sensor and battery replacement, this analyzer
should only be opened and ser viced by au tho rized person-
nel.
When testing an appliance, a full visual in spec tion of the
appliance should be carried out to ensure its safe op er a tion.
Basic
Reporting
24-8250 24-8251
HARD CARRY CASE X X
PROBE ASSEMBLY X X
PRINTER IRDA X
BOOT X X
PC SOFTWARE X
USB CABLE X
BATTERIES X X
QUICK START GUIDE X X
4.10 Emptying the Water Trap.......................................................27
4.11 Powering OFF the Analyzer & Purging ............................... 28
4.12 Low Battery Alarm ................................................................ 28
4.13 Memory ................................................................................... 28
4.14 Printing Test Data ................................................................. 30
4.15 Fyrite
®
User Software Installation ..................................... 31
4.16 Fyrite
®
User Software Description ....................................... 34
5.0 Calibration & Maintenance ......................................................35
5.1 B-Smart Sensors ...................................................................... 35
5.2 Starting a Calibration ............................................................. 35
5.3 B-Smart Sensor Replacement & Calibration ......................... 37
5.4 Pressure Sensor Calibration ................................................... 37
5.5 T-Stack Calibration.................................................................. 39
5.6 T-Air Calibration ..................................................................... 41
5.7 CO Sensor Calibration ............................................................. 43
6.0 Maintenance ................................................................................. 44
6.1 Fyrite
®
INSIGHT Disassembly ............................................. 44
6.2 Water Trap / Filter ................................................................. 46
6.2.1 Emptying the Water Trap Chamber .................................... 46
6.2.2 Replacing the Filter Element ............................................... 46
6.3 O
2
Sensor Replacement .......................................................... 47
6.4 CO Sensor Replacement ......................................................... 48
6.5 Thermocouple Replacement .................................................... 49
6.6 Gas Pump Replacement .......................................................... 50
6.7 Cleaning the Probe ................................................................. 50
6.8 Error Messages ....................................................................... 51
6.9 Diagnostics Screen ................................................................. 52
6.10 Status Screen ......................................................................... 53
7.0 Parts & Service ............................................................................ 54
7.1 Replacement Parts .................................................................. 54
7.2 Accessories .............................................................................. 54
7.3 Service Centers ....................................................................... 55