Technical data
Vitodens 200-W B2HA 19, 28, 35 Service
31
5683 702 - 07
Outdoor Reset Programming Unit
Installation Examples
Matching the control unit to the heating system
The control unit must be matched to the equipment level of the system. Various system components are recognized
automatically by the control unit and the relevant codes are adjusted automatically.
- For the selection of an appropriate type, see the following diagrams.
- For coding steps, starting on page 39.
System type 1
System Examples for codes 00:1 and 00:2
Heating system with one heating circuit without mixing
valve A1 with/without DHW heating, with/without low
loss header.
Function/system components Code
Adjust Group
One heating circuit without mixing
valve A1 (heating circuit 1),
without DHW heating
00:1 General/1
One heating circuit with mixing
valve A1 (heating circuit 2), with
DHW heating (code is adjusted
automatically)
00:2 General/1
System with low loss header 04:0 Boiler/2