Technical data
5683 702 - 07
34
Installation Examples (continued)
Function/system components Code
Adjust Group
System only with two heating
circuits with mixing valve with
extension kit for mixing valve
(without unregulated heating
circuit)
- with DHW tank
- without DHW tank
00:8
00:7
General/1
System with low loss header 04:0 Boiler/2
System type 4
System Example for code 00:7 and 00:8
Heating system with one heating circuit with mixing
valve, one heating circuit with mixing valve M2 (with
extension kit), one heating circuit with mixing valve M3
(with extension kit) and low loss header (with/without
DHW heating).
Function/system components Code
Adjust Group
System with one heating circuit
without mixing valve A1 (heating
circuit 1), one heating circuit with
mixing valve M2 (heating circuit 2)
and one heating circuit with mixing
valve M3 (heating circuit 3), without
DHW heating (code is adjusted
automatically)
- without DHW tank
- with DHW tank
00:9
00:10
General/1
System with low loss header 04:0 Boiler/2
System type 5
System Example for code 00:9 and 00:10
Heating system with one heating circuit with mixing
valve, one heating circuit with mixing valve M2 (with
extension kit), one heating circuit with mixing valve M3
(with extension kit) and low loss header (with/without
DHW heating).
Outdoor Reset Programming Unit
Vitodens 200-W B2HA 19, 28, 35 Service