Specifications

Instruction 24-9395
12
Fyrite Pro
3.5 Setup Mode
The analyzer is preset at the factory for the parameters shown below, but
can be changed as described in their associated sections.
Function Parameter To Change
Fuel Natural Gas (F1) Section 4.13.5
Temperature Unit °F Section 3.5.2
CO Channel Auto Zero (A2) Section 3.5.3
Draft (Pressure) WC Section 3.5.4
Clock Not Initialized Section 3.5.5 thru 3.5.7
Printer Protocol IrDA Section 3.5.8
3.5.1 Entering Setup
1. With the analyzer turned OFF, press and hold down the HOLD
button.
2. Press the I/O button.
3. Release both buttons.
4. The analyzer is now in its Setup Mode. Refer to Sections 3.5.2 thru
3.5.8 for information on how to set up each analyzer parameter.
3.5.2 Selecting Temperature Units
The Temperature Setup Screen is labeled “Unit.
1. Enter the Setup Mode per Section 3.5.1. If necessary, repeatedly
press the ENTER button until “Unit” is displayed.
2. Press the or button until the desired temperature unit (°F or
°C) is displayed.
3. Press ENTER to move to the next Setup Screen, or I/O to exit setup.