ENGLISH / 2015/16 IT POWER SOLUTIONS Innovative products for the IT infrastructure
IT POWER SOLUTIONS Contents IT POWER SOLUTIONS Passive PDUs Basic PDU 19" 1 U .................................................................................. 12 Basic PDU 19" > 1 U .............................................................................. 16 Basic PDU 19" 2 U .................................................................................. 18 Basic PDU Vertical ..................................................................................
IT POWER SOLUTIONS Contents Intelligent distributors & retrofit solutions BlueNet BN2000 Inline ............................................................................ 54 Power metering via local display and network BlueNet BN2000 Inline PLC .................................................................... 56 Power metering via local display, network and PowerLine BlueNet Power Unit 2 U (modular) ..........................................................
IT POWER SOLUTIONS Function modules World of opportunities •••••••••••••••••••••••••••••• Function modules can be integrated ex factory Overvoltage protection These days the failure of electrical and electronic equipment is a real nightmare scenario. Protection against excess electric voltage is more important than ever for electrical and electronic equipment. "24/7 availability" is now essential for many users. Don't worry: the Bachmann strip with built-in overvoltage protection is the answer.
IT POWER SOLUTIONS Function modules RCM RCM is the abbreviation for Residual Current Monitor. The use of an RCM allows drops in the level of insulation (creepage / leakage currents) of a power supply to be detected during operation before a high residual current causes protective devices to trip. BlueNet BN3000 BlueNet BN3000 has an optimised shape factor, PDUs that can be cascaded via Modbus and a rotatable OLED display.
IT POWER SOLUTIONS IT POWER SOLUTIONS Bachmann IT POWER SOLUTIONS Systematic power distribution 40 years of experience in developing, manufacturing and distributing power distribution solutions. True to this history, Bachmann is synonymous with high-quality and innovative electronics and high measurement accuracy, packaged in extremely robust aluminium housings. We provide solutions in IT energy distribution. Our intelligent and modular product range provides great peace of mind.
IT POWER SOLUTIONS Bachmann - quality that connects Research & development ∙ ∙ ∙ ∙ Company's sites in Germany and China Company's labs for running function and safety tests Certification in line with the strictest standards (e.g. DIN EN ISO 9001) Strong development network with external partners Sales ∙ ∙ ∙ ∙ ∙ IT SUBSIDIARIES: Bachmann Romania S.R.L., Medias / Romania Bachmann Hong Kong Ltd., Hong Kong / China Bachmann SARL Tremblay / France Bachmann Electrical Engineering Ltd.
IT POWER SOLUTIONS IT POWER SOLUTIONS Modular PDU inserts In our IEC320 C13 power strips, the C14 plugs can be reliably locked with a PVC clip.
IT IT POWER SOLUTIONS Integration of devices installed in series RCD (residual current protection device) RCM (residual current monitor) RCM is the abbreviation for Residual Current Monitor. RCD is the abbreviation for Residual Current Protective Device. If an insulation error causes a dangerous contact voltage, RCDs have the job of interrupting all the poles on operating equipment within 0.2 or 0.4s.
IT POWER SOLUTIONS IT POWER SOLUTIONS Bachmann IT Power Distribution guarantees a safe connection IEC320 C13 lockable Two locking clips to secure two power cables. IEC320 C13 with IEC lock can be supplied. IEC320 C19 with IEC lock The IEC lock system protects computers, as servers and electrical equipment can become accidentally disconnected due to vibrations. The benefits at a glance ∙ ∙ ∙ ∙ 10 Plugs locked using PVC clip or IEC lock.
IT IT POWER SOLUTIONS Bachmann IT Power Distribution in high-quality aluminium housing The benefits at a glance ∙ ∙ ∙ ∙ ∙ Space-saving integration of PDU in the server rack with scope for modular add-ons High-quality and very robust aluminium profile Extremely compact dimensions of 44 x 47 mm.
IT POWER SOLUTIONS IT PDU Basic 1 U IT PDU Basic 1 U Power Distribution Units 230 V / 50 Hz With its IT-PDU 1 U, Bachmann provides a huge choice of PDUs in a high-quality aluminium profile. With their extremely compact size of just 1 height unit, 44 mm in depth and 19" in width, the PDUs can be easily integrated in your IT rack. Their multi-functional mounting brackets allow the units to be mounted in various ways (e.g. inwardly recessed). Our high quality standards ensure that the contact is reliable.
IT PDU Basic 1 U 19" IT PDU Basic (230 V / 50 Hz) Art. no. Version Colour (plastic / profile) 19" IT PDU Basic Without switch, 2.0 m H05VV-F 3G 1.50 mm², black, with right angle plug with earthing contact 333.401 ∙ 9 x socket outlet with earthing contact light grey 333.506 ∙ 9 x socket outlet with earthing contact black light grey / silver black / black 333.539 ∙ 9 x IEC320 non-heating appliance socket C13 black light grey / silver 333.
IT POWER SOLUTIONS IT PDU Basic 1 U IT PDU Basic (230 V / 50 Hz) Art. no. Version Colour (plastic / profile) IT PDU Basic Without switch, 2.0 m H05VV-F 3G 1.50 mm², black, with right angle plug with earthing contact 333.413 ∙ 12 x socket outlet with earthing contact light grey light grey / silver 10" IT PDU Basic (230 V / 50 Hz) Art. no. Version Colour (plastic / profile) IT PDU Basic 10 ", 2.0 m H05VV-F 3G 1.50 mm², black, with right angle plug with earthing contact 333.
IT PDU Basic 1 U IT PDU Basic Switzerland Art. no. Version Colour Supply cable 19" IT PDU Basic Switzerland Without switch 800.1259 8 x CH type 13 90° black 2.0 m H05VV-F 3G 1.0mm2, with CH plug type 12 800.1262 8 x CH type 23 90° black 3.0 m H05VV-F 3G 1.5mm2, with CH plug type 23 800.1263 7 x CH type 13 90° black 800.1264 7 x CH type 23 90° black With switch 2.0 m H05VV-F 3G 1.0mm2 with CH plug type 12 3.0 m H05VV-F 3G 1.
IT POWER SOLUTIONS IT PDU Basic 1 U PDUs > 1 U ALU Power distribution units ∙ ∙ ∙ ∙ ∙ ∙ Torsionally rigid profile > 1 U (52 mm), profile depth 44 mm Modular socket outlet design Standard socket colour white; other colours black, yellow, red, brown, blue and green also available Optionally includes illuminated 2-pole switch High-quality electronics components built in, e.g. overvoltage protection, mains and frequency filters Mounting brackets included End caps riveted and do not open Power input: 2.
IT PDU Basic 1 U PDUs > 1 U PVC Power distribution units ∙ ∙ ∙ ∙ Torsionally rigid profile > 1 U (52 mm) in high-quality PVC, profile depth 44 mm Optionally includes illuminated 2-pole switch High-quality electronics components built in, e.g. overvoltage protection, mains and frequency filters Mounting brackets included End caps riveted and do not open Power input: 2.0 m, H05VV-F 3G 1.
IT POWER SOLUTIONS IT PDU Basic 2 U With increased distance between socket recesses (15 mm), allowing easy positioning of mains adaptor plugs and operating equipment. With integrated terminal for power cable and additional outlet for separate earth conductor. Screwed and rewireable 2 m supply cable H05VV-F 3G 1.
IT PDU Basic 2 U 2 U PDU set at 90° ∙ Supply cable: 2.0 m H05VV-F 3G 1.50 mm², black, with right angle plug with earthing contact ∙ Socket inserts, black, 15 mm spacing between sockets Art. no. Version Dimensions: (L x W x H) Power strip 90° 19" Without switch 300.000 ∙ 6 x socket outlet with earthing contact approx. 445 x 74 x 45 mm 300.001 ∙ 9 x socket outlet with earthing contact approx. 617 x 74 x 45 mm 300.002 ∙ 12 x socket outlet with earthing contact approx.
IT POWER SOLUTIONS Basic PDU Vertical Basic PDU Vertical Power distribution units 230 - 400 V / 50 Hz Development of the IT PDU focused on space-saving PDU integration in the server rack with scope for modular expansion. The high-quality and very robust aluminium profile measures a compact 44 x 47 mm. The space-saving design therefore provides space for data cabling and ventilation for cooling the server rack.
Basic PDU Vertical Sample rack configuration Sample system for 4 x 3 x 16 A / 400 V = 44 KW (11 KW per Basic PDU) IT PDU Basic 1 U 18 x IEC C320 C13 with interlock 3 x IEC C320 C19 with interlock Split into 3 phases Art. no. 800.0104 (See page 24) IT PDU Basic 1 U 12 x IEC C320 C13 with interlock 6 x socket outlet with earthing contact Split into 3 phases Art. no. 800.0109 (See page 24) IT PDU Basic 1 U 18 x IEC C320 C13 with interlock 3 x IEC C320 C19 with interlock Split into 3 phases Art. no. 800.
IT POWER SOLUTIONS Basic PDU Vertical High density rack Sample system for 4 x 3 x 16 A / 400 V = 44 kW (11 kW per feeder unit) Basic PDU 16 A / 400 V / 50 Hz 800.0113 800.0113 (See page 24) Supply A 16 A / 400 V / 50 Hz (See page 24) Supply B 16 A / 400 V / 50 Hz Supply A 16 A / 400 V / 50 Hz The benefits at a glance ∙ PDU with double infeed to increase performance or map redundancies.
Basic PDU Vertical Blade center rack Sample system for 2 x 3 x 32 A/400 V = 44 kW (22 kW per Basic PDU) Basic PDU 32 A / 400 V / 50 Hz IT PDU Basic 1 U IT PDU Basic 1 U 6 x IEC C320 C19 with interlock Each socket is protected by a C16A MCB Split into 3 phases Art. no. 800.0101 (See page 24) (See page 24) Supply A 32 A / 400 V / 50 Hz Supply B Basic PDU Vertical 6 x IEC C320 C19 with interlock Each socket is protected by a C16A MCB Split into 3 phases Art. no. 800.
IT POWER SOLUTIONS Basic PDU Vertical Basic PDU Vertical 230 16 CEE 1 230 32 Plug Dimensions (WxHxD) in mm 1 Outlets in total CEE 6 6 482.
Accessories Accessories Mounting kits for IT PDUs ∙ Power strip is fixed by insertion into the profile groove provided ∙ No additional screws required Art. no. Version 1 U mounting brackets 940.143 ∙ Mounting brackets left and right 1 U link 800.0053 ∙ For connecting 2 vertically fitted PDUs Locking clips 940.103 ∙ Red locking clip for IEC 320 non-heating appliance sockets C13, supplied in packs of 12. Cable crosssection mm² Cable length (m) Plug Coupling Art. no. Cable colour Art. no.
IT POWER SOLUTIONS BlueNet BlueNet The intelligent, modular energy management system BlueNet offers a total solution for structuring, controlling and monitoring IT power networks. It captures consumption and output data and provides the user with relevant data and control options for modern power management.
BlueNet Energy management Monitor energy costs with BlueNet. All data, such as current, voltage, power, is depicted by the software and display. Loads can then be distributed such that failures due to circuit overloads no longer occur. Messages can be triggered automatically by means of adjustable threshold valves. Restarts controlled by web link further increase availability and flexibility.
IT POWER SOLUTIONS BlueNet / Product matrix BlueNet product matrix BN0500 BN1000 BN2000 BN2000 PLC BN2000 Inline BN2000 Inline PLC BN3000 Managed Power unit Current x x x x x x x x x Voltage x x x x x x x x x Phase angle x x x x x x x x x Frequency x x x x x x x x x Effective power x x x x x x x x x Reactive power x x x x x x x x Apparent power x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
BlueNet / Product matrix BN0500 BN1000 BN2000 BN2000 PLC BN2000 Inline BN2000 Inline PLC BN3000 Switched Managed Power unit x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x SWITCH Timer function x Threshold value switching function x COMMUNICATION Ethernet (10/100 Mbit/s) x WiFi 802.
IT POWER SOLUTIONS BlueNet / BN0500 BlueNet BN0500 Current and power metering via local display Power measurement (kW) The effective power drawn by the consumers, taking the phase angle into account. Power consumption of the connected devices. Mains voltage (V) Displays the voltage of the incoming mains supply to which the power meter is connected. Phase angle Displays the phase shift in the power network.
BlueNet / BN0500 BlueNet BN0500 (16 A / 230 V / 50 Hz) Integrated measurement of: ∙ current, effective power, voltage, frequency, phase angle and energy ∙ Indication on illuminated LCD ∙ Energy meter which can be reset (value is stored even if there is no power supply) ∙ Accuracy of measurement +/- 1 % ∙ End caps riveted and do not open ∙ Includes mounting brackets and screws ∙ Plastic black, aluminium profile silver Art. no. Version Dimensions (L x W x H) BlueNet BN0500 integrated power metering, 2.
IT POWER SOLUTIONS BlueNet / BN1000 WIFI ANTENNA The BlueNet BN1000 module is available with an internal or external antenna. MODULARITY On request, all BlueNet WiFi/LAN products are also available with RCDs, RC circuit breakers, miniature circuit breakers, complete device protection or, for example, thermal fuse. METERING + SWITCHING 3 switching groups of 16 A each, can be switched manually or automatically depending on load, temperature and time. Optional permanent socket outlets.
BlueNet / BN1000 combined with connector systems, basic products and other components. Manual switching The WiFi/LAN module is accessed by Internet browser or mobile app. A static or dynamic IP address of the local network is assigned to the WiFi/LAN module. A dynamic DNS is fully supported and allows access (including remote access) to connected WiFi/LAN products with all functions, such as switching the switching outputs and monitoring of temperature and power data at any time.
IT POWER SOLUTIONS BlueNet / BN1000 App for smartphones or tablet PCs The app is available from the Play Store (for Android) or the App Store (for iOS) by searching for BlueNet WiFi. The present temperature, current switching statuses and current power metering data are displayed. The socket outlets can be switched on and off. If a Dynamic DNS address is entered, this entire functional scope can be accessed remotely via 3G or 4G.
BlueNet / BN1000 BlueNet Website interface 35
IT POWER SOLUTIONS BlueNet / BN1000 Power metering & switching (BlueNet BN1000) ∙ Power metering ∙ Temperature monitoring ∙ Issuing of threshold value alarms ∙ Remote switching ∙ Time-controlled switching ∙ Temperature-dependent switching 16 3,7 820.030 H05VV-F 3G1,5 2 SKS* 1 230 16 3,7 820.032 H05VV-F 3G1,5 2 T12 1 230 16 3,7 820.029 H05VV-F 3G1,5 2 SKS* 1 230 16 3,7 820.031 H05VV-F 3G1,5 2 SKS* 1 230 16 3,7 820.033 H05VV-F 3G1,5 2 T12 1 230 16 3,7 820.
BlueNet / BN1000 BN1000 accessories Art. no. Description BlueNet BN1000 accessories 820.045 820.046 820.047 ∙ External temperature sensor 3.0 m; jack plug 2.5 mm; measuring range of sensor max. -50 °C to 110 °C ∙ External temperature sensor 10 m; jack plug 2.5 mm; measuring range of sensor max. -50 °C to 110 °C; water-tight IP88 ∙ External temperature sensor 20 m; jack plug 2.5 mm; 820.048 measuring range of sensor max.
IT POWER SOLUTIONS BlueNet / BN2000 BlueNet BN2000 Mains voltage (V) Displays the voltage of the incoming mains supply to which the power meter is connected. Current (A) The current now being drawn by the connected devices. 230 V 12.5 A 50.00 Hz PF 0.966 2.77 kW MODE Frequency (Hz) Current mains frequency Power factor Displays the power factor. DELTA Power measurement (kW) The effective power drawn by the consumers, taking the phase angle into account. Power consumption of the connected devices.
BlueNet / BN2000 Combined temperature and air humidity sensor which can be easily secured to the rack using the integrated magnet.
IT POWER SOLUTIONS BlueNet / BN2000 Current (A) Max power in kVA 230 16 3.7 329.3010 H05VV-F 1.5 2 ECP* 1 230 16 3.7 8 329.3012 H05VV-F 1.5 3 CEE 3 400 16 11.0 36 329.3013 H05VV-F 1.5 3 CEE 3 400 16 11.0 36 329.3056 H05VV-F 4 3 CEE 1 230 32 7.4 24 4 329.3057 H05VV-F 2.5 3 CEE 1 230 16 3.7 24 3 329.3058 H05VV-F 4 3 CEE 3 400 32 22.1 24 6 329.3059 H05VV-F 2.5 3 CEE 3 400 16 11.
BN2000 / Accessories Accessories Mounting kits for IT PDUs ∙ Power strip is fixed by insertion into the profile groove provided ∙ No additional screws required Art. no. Version 1 U mounting brackets 940.143 ∙ Mounting brackets left and right 1 U link 800.0053 ∙ For connecting 2 vertically fitted PDUs Locking clips 940.103 ∙ Red locking clip for IEC 320 non-heating appliance sockets C13, supplied in packs of 12. Cable crosssection mm² Cable length (m) Plug Coupling Art. no. Cable colour Art.
IT POWER SOLUTIONS 1 BlueNet / BN2000 PLC 2 3 500 Power connection cable Ethernet 10/100 Mbps BlueNet BN2000 PLC (PowerLine communication) 16 - 32 A / 230 - 400 V / 50 Hz The benefits at a glance ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ 42 Robust aluminium housing 1-phase and 3-phase versions 3.
BlueNet / BN2000 PLC Benefits of PowerLine technology ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ The PLC module can be combined with all BlueNet BN2000 products Narrowband PowerLine Communication (PLC) with high availability and not susceptible to disturbances Data from any number of PDUs is managed centrally using a concentrator Optimisation of investment and operating costs through reduction in network cabling, patch cabling, IP addresses and switch ports No additional space needed in the PDU for the PLC module No cable-lined rad
IT POWER SOLUTIONS BlueNet / BN2000 PLC BlueNet BN2000 PLC Phase(s) Rated voltage (V) Current (A) Max power in kVA C13 CEE 3 400 16 11.0 36 329.3112 H05VV-F 4 3 CEE 1 230 32 7.4 24 4 329.3113 H05VV-F 2.5 3 CEE 1 230 16 3.7 24 3 329.3114 H05VV-F 4 3 CEE 3 400 32 22.1 24 6 329.3115 H05VV-F 2.5 3 CEE 3 400 16 11.0 24 6 Length (mm) Plug 3 on request Cable length (m) 2.
BN2000 PLC / Accessories Accessories Mounting kits for IT PDUs ∙ Power strip is fixed by insertion into the profile groove provided. ∙ No additional screws required Art. no. Version 1 U mounting brackets Zero U Space 940.143 ∙ Mounting brackets left and right 1 U link Zero U Space 800.0053 ∙ For connecting two vertically fitted PDUs Locking clips 940.103 ∙ Red locking clip for IEC 320 non-heating appliance sockets C13, supplied in packs of 12.
IT POWER SOLUTIONS BlueNet / BN3000 master – slave Measurement Current, power (effective, apparent and reactive power), energy consumption, voltage, frequency, power factor, N conductor ESC ACTIVE CURRENT L1 12.1 A L2 12.0 A L3 11.4 A Integrated display The most important measured values at rack level at a glance. Overview Shows the measured values of all phases in an overview. Scrolling Display can be rotated The keys on the front can be used to scroll through the various measured values.
BlueNet / BN3000 master – slave BlueNet BN3000 master / slave 16 - 32 A / 230 - 400 V / 50 Hz ESC ESC ACTIVE CURRENT L1 12.1 A L2 12.0 A L3 11.4 A Connection mode With BlueNet, the slave PDUs also have a display with the same scope of function as the master PDUs. Up to 9 slave PDUs are connected to the master PDUs via Modbus. Extra environmental sensors can be connected to each PDU. Ethernet connection 802.3019 32 A / 400 V / 50 Hz BlueNet allows different kinds of PDUs to be connected to a bus.
IT POWER SOLUTIONS BlueNet / BN3000 master – slave BlueNet BN3000 master / slave 16 - 32 A / 230 - 400 V / 50 Hz Cable type Cable cross-section mm² Cable length (m) Plug Phase(s) Rated voltage (V) Current (A) Max power in kVA C13 C19 SOEC** Outlets in total 802.3004 802.3004-S H05VV-F 2.5 3 CEE* 1 230 16 3.7 16 4 0 20 802.3005 802.3005-S H05VV-F 4 3 CEE 1 230 32 7.4 16 4 0 20 802.3006 H05VV-F 2.5 3 CEE 1 230 16 3.7 16 0 4 20 802.
BN3000 Master – slave / accessories Cable colour Cable crosssection mm² Cable length (m) Plug Coupling 356.119 black 1.0 0.50 C14 C13 356.169 black 1.0 0.75 C14 C13 356.120 black 1.0 1.00 C14 C13 356.127 black 1.0 1.50 C14 C13 356.171 black 1.0 2.00 C14 C13 356.172 black 1.5 0.50 ECP* C13 356.1721 black 1.5 0.75 ECP* C13 356.1722 black 1.5 1.00 ECP* C13 356.1723 black 1.5 1.50 ECP* C13 354.127 black 1.5 2.00 ECP* C13 356.1731 black 1.5 0.
IT POWER SOLUTIONS BlueNet / Residual current monitoring Maximum availability and safety with BlueNet RESIDUAL CURRENT MONITORING (RCM) Using residual current monitoring allows changes in the level of insulation to be detected at an early stage before protective devices are tripped by a high residual current, that puts people at risk and involves the risk of fire.
Cable cross-section mm² Cable length (m) Plug Phase(s) Rated voltage (V) Current (A) Max power in kVA C13 C19 SOEC** Outlets in total from stock H05VV-F 2.5 3 CEE 3 400 16 11.0 18 3 0 21 OR 802.3023 H05VV-F 2.5 3 CEE 3 400 16 11.0 18 0 3 21 OR Article number for slave variant 802.3022 Article number Cable type BlueNet / Residual current monitoring 802.3024 802.3024-S H05VV-F 2.5 3 CEE 3 400 16 11.0 24 6 0 30 OR 802.3025 802.
IT POWER SOLUTIONS BlueNet / Switched BlueNet Switched Power distribution units ∙ ∙ ∙ ∙ ∙ ∙ ∙ Socket outlets can be switched individually Safe zero-voltage switching Integrated LED switching status check per port Integrated Ethernet connection Operated via a web browser Includes the following protocols: HTTP, HTTPS, SNMP, SMTP, NTP, SSH Robust aluminium housing BlueNet Switched PDU 1-phase (16 A / 230 V / 50 Hz) Art. no. Version Dimensions (L x W x D) BlueNet Switched 1-phase 19", 2.
BlueNet / Managed BlueNet Managed Power distribution units ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ Socket outlets can be switched individually Safe zero-voltage switching Integrated LED switching status check per port Integrated Ethernet connection Operated via a web browser Integrated measurement of current, effective power, voltage, frequency and phase angle Includes the following protocols: HTTP, HTTPS, SNMP, SMTP, NTP, SSH Robust aluminium housing Illuminated LCD BlueNet Managed PDU Art. no.
IT POWER SOLUTIONS BlueNet / BN2000 Inline BlueNet BN2000 Inline 16 - 32 A / 230 - 400 V / 50 Hz The BlueNet BN2000 Inline is an easy-to-install intelligent system for monitoring and displaying energy use. The product is particularly suited to data centres and industrial applications. The BlueNet BN2000 Inline can be quickly and cheaply integrated in existing and new infrastructures using the integrated terminal block or the connection cable that has already been fitted.
BlueNet / BN2000 Inline Designed for use in production, the BlueNet BN2000 Inline series is ideal for production facilities. BlueNet BN2000 Inline Art. no. Phases Voltage V Current A Power in kVA from stock Dimensions (mm) 329.3032 1 230 16 3.7 yes 232 x 104 x 102 329.3033 3 400 16 11.0 yes 232 x 104 x 102 329.3037 3 400 32 22.1 yes 232 x 104 x 102 329.3032 329.3033 Art. no. BlueNet BlueNet BN2000 accessories Description BlueNet BN2000 accessories 329.
IT POWER SOLUTIONS BlueNet / BN2000 Inline PLC BlueNet BN2000 Inline PLC Benefits of PowerLine Mains voltage (V)technology Displays the voltage of the incoming mains supply to which the power meter is connected. Current (A) The current now being drawn by the connected devices. 230 V 12.5 A 50.00 Hz PF 0.966 2.77 kW MODE Frequency (Hz) Current mains frequency Power factor Displays the power factor.
BlueNet / BN2000 Inline PLC BlueNet BN2000 Inline PLC Art. no. Phases Voltage V Current A Power in kVA from stock Dimensions (mm) 329.3060 1 230 16 3.7 OR 232 x 104 x 102 329.3061 3 400 16 11.0 OR 232 x 104 x 102 329.3062 1 230 32 7.4 OR 232 x 104 x 102 329.3063 3 400 32 22.1 OR 232 x 104 x 102 329.3060 329.
IT POWER SOLUTIONS BlueNet / Power Unit 2 U BlueNet Power Unit 2 U (Modular) 16 - 32 A / 230 - 400 V / 50 Hz The BlueNet Power Unit offers a modular platform for power distribution in data centres. The Power Unit base unit provides power distribution in the rack. If necessary, the measurement module can be retrofitted or replaced during operation without interrupting the supply. The benefits at a glance ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ ∙ 58 3.
BlueNet / Power Unit 2 U BlueNet Power Unit The measurement module can be replaced during operation without interrupting the supply to the connected devices. 2 U high, 19" wide (1 U is 44.45 mm) Current, effective power, voltage, frequency, phase angle and energy can be read from the LC display on the front of the unit. LEDs indicate whether there is voltage present on each of the phases.
IT POWER SOLUTIONS BlueNet / Power Unit 2 U BlueNet Power Unit 16 A / 230 V / 50 Hz Sample system for 2 x 16 A/230 V = 7.2 kW BlueNet Power Unit with measurement module Art. no. 329.9015 and 329.9010 Supply A 16 A / 400 V / 50 Hz (1.8kW per C19 output) BlueNet Power Unit with measurement module Art. no. 329.9015 and 329.9010 Supply B 16 A / 400 V / 50 Hz Plug-in energy distribution system including measurement module for blade systems, switches etc. with high power consumption per port.
BlueNet / Power Unit 2 U Upgrade solution Sample system for 2 x 16 A / 230 = 7.2 kW (3.6 kW per CEE output) BlueNet Power Unit with measurement module Art. no. 329.9014 and 329.
IT POWER SOLUTIONS BlueNet / Power Unit IT PDU Basic U 18 x IEC C320 C13 with interlock 3 x IEC320 C13 with interlock Split into 3 phases Art. no. 800.0104 IT PDU Basic U 18 x IEC C320 C13 with interlock 3 x IEC320 C13 with interlock Split into 3 phases Art. no. 800.0104 BlueNet Power Unit with measurement module 329.9008 + 329.
BlueNet / Power Unit IT PDU Basic U IT PDU Basic U 36 x IEC C320 C13 with interlock Split into 3 phases Art. no. 800.0102 36 x IEC C320 C13 with interlock Split into 3 phases Art. no. 800.0102 Supply B Supply A 32 A / 400 V / 50 Hz 32 A / 400 V / 50 Hz BlueNet Power Unit with measurement module 329.9012 + 329.
IT POWER SOLUTIONS BlueNet / Power Unit The measurement module can be replaced during operation without interrupting the supply to the connected devices.
BlueNet / Power Unit BlueNet Power Unit base unit (measurement module is available separately) Art. no. Input Output BlueNet Power Unit 482.6 x 88 x 317 mm 2 x 1 phase 230 V 329.9007 ∙ 2 x 3.0 m CEE 16 A / 230 V ∙ 4 x CEE 16 A / 230 V 329.9014 ∙ 2 x 3.0 m CEE 16 A / 230 V ∙ 2 x CEE 16 A / 230 V 329.9015 ∙ 2 x C20 16 A / 230 V ∙ 4 x C19 16 A / 230 V 329.9016 ∙ 2 x C20 16 A / 230 V ∙ 2 x C19 16 A / 230 V 2 x 3 phase 400 V 329.9008 ∙ 2 x 3.0 m CEE 16 A / 400 V ∙ 4 x CEE 16 A / 400 V 329.
IT POWER SOLUTIONS BlueNet / Power Unit 3 U The measurement module can be replaced during operation without interrupting the supply to the connected devices. 2 U high, 19" wide (1 U is 44.45 mm) Current, effective power, voltage, frequency, phase angle and energy can be read from the LC display on the front of the unit. LEDs indicate whether there is voltage present on each of the phases. A built-in Ethernet port lets you export readings and set alarm thresholds via a web browser or SNMP.
BlueNet / Power Unit 3 U BlueNet Power Unit 32 A / 400 V / 50 Hz IT PDU Basic 1 U 9 x socket outlet with earthing contact IT PDU Basic 1 U 9 x socket outlet with earthing contact Supply B 32 A / 400 V / 50 Hz Supply A 32 A / 400 V / 50 Hz BlueNet Power Unit 3 U with measurement module 329.9024 + 329.9022 BlueNet Power Unit 3 U (basic unit) including 12 integrated C16A miniature circuit breakers (measurement module available separately) Art. no. Input Output BlueNet Power Unit 3 U base unit 482.
IT POWER SOLUTIONS Accessories Accessories Mounting kits for IT PDUs · The brackets are screwed to the PDU end cap using a screw connection (screws provided). Art. no. Version 1 U mounting brackets 940.142 ∙ Mounting brackets left and right > 1 U mounting brackets 940.096 ∙ Mounting brackets left and right Mounting brackets for VM profile variant / universal installation · Power strip is fixed by insertion into the profile groove provided · No additional screws required Art. no.
Accessories Cable colour Cable crosssection mm² Cable length (m) Plug Coupling 356.119 black 1.0 0.50 C14 C13 356.169 black 1.0 0.75 C14 C13 356.120 black 1.0 1.00 C14 C13 356.127 black 1.0 1.50 C14 C13 356.171 black 1.0 2.00 C14 C13 356.172 black 1.5 0.50 ECP* C13 356.1721 black 1.5 0.75 ECP* C13 356.1722 black 1.5 1.00 ECP* C13 356.1723 black 1.5 1.50 ECP* C13 354.127 black 1.5 2.00 ECP* C13 356.1731 black 1.5 0.50 C20 C19 356.
IT POWER SOLUTIONS Accessories Locking cap IEC320 C13 & C19 Art. no. Version Connecting cable for interlock 800.0050 ∙ C19 locking caps, 10 items incl. unlocking tool 800.0051 ∙ C13 locking caps, 10 items incl. unlocking tool 800.0052 ∙ Unlocking tool for locking cap RackFix tool-free mounting on 19" rail · Self-locking fixing connector for tool-free fastening of PDUs in 19" rack Art. no. Version RackFix tool-free rack fastening 940.166 ∙ Fixing clip, supplied in packs of 50 940.
Accessories Data cables –> Transfer of data within various categories Art. no. Length Version CAT5e patch cable plug/plug 918.003 1.0 m ∙ CAT5e cable, shielded, colour grey 940.052 3.0 m ∙ Conforms to ISO / IEC 11801 and EN 50173 940.053 5.0 m ∙ Ends 1 and 2: RJ45 plug with protective rubber sleeve and protective tongue for interlock ∙ Suitable for e.g. CAT5e socket / socket 940.057 CAT6 patch cable plug / plug 940.040 3.0 m ∙ CAT6 cable, shielded, colour grey 940.041 5.
Ernsthaldenstr. 33 / 70565 Stuttgart / Deutschland Telephone +49 711 866 02-0 / Telefax +49 711 866 02-34 info@bachmann.com / www.bachmann.com assume no responsibility for any mistakes or printing errors contained herein. 2015.KITEN // We reserve the right to make technical modifi cations to the products described in this document and Bachmann GmbH & Co.