Specifications
www.milwaukeeinst.com
PO
4/
Fe/I
41
MW12/MW13/MW14
New
Specifications
MW12 MW13 MW14
Phosphate Iodine Iron
Range 0.00 to 2.50 ppm 0.0 to 12.5 ppm 0.00 to 5.00 ppm
Resolution 0.01 ppm 0.1 ppm 0.01 ppm
Accuracy ±0.04 ppm ±4% of reading @ 25 °C ±0.1 ppm ±5% of reading @ 25 °C ±0.04 ppm ±2% of reading @ 25 °C
Typical EMC Dev. ±0.01 ppm ±0.1 ppm ±0.01 ppm
Light Source Light Emitting Diode @ 525 nm Light Emitting Diode @ 525 nm Light Emitting Diode @ 525 nm
Light Detector Silicon Photocell Silicon Photocell Silicon Photocell
Method Adaptation of the Standard Methods Adaptation of the Standard Methods Adaptation of the EPA Phenantroline
fo the Examination of Water and for the Examination of Water and method 315B, for natural and treated
Wastewater, 20th edition, Ascorbic Wastewater, 18th edition, DPD waters. The reaction between iron
Acid method. The reaction between method. The reaction between and reagent causes an orange tint
phosphate and the reagent causes iodine and the reagent causes a in the sample.
a blue tint in the sample. pink tint in the sample.
Environment 0 to 50°C (32 to 122 °F) max. 0 to 50°C (32 to 122 °F) max. 0 to 50°C (32 to 122 °F) max.
95% RH non-condensing 95% RH non-condensing 95% RH non-condensing
Battery Type 1 x 1.5V AAA 1 x 1.5V AAA 1 x 1.5V AAA
Auto-Shut Off After 2 minutes of non-use After 2 minutes of non-use After 2 minutes of non-use
Dimensions 81.5 x 61 x 37.5 mm 81.5 x 61 x 37.5 mm 81.5 x 61 x 37.5 mm
(3.2 x 2.4 x 1.5”) (3.2 x 2.4 x 1.5”) (3.2 x 2.4 x 1.5”)
Weight 64 g (2.25 oz.) 64 g (2.25 oz.) 64 g (2.25 oz.)
Accessories
2720115
Phosphate powder reagent, (25 pcs)
2
720316
Iodine powder reagent (25 pcs)
2
720416
Iron powder reagent, (25 pcs)
3
000100
Glass cuvets with caps (2 pcs)
3
000200
Tissue for wiping cuvets (2 pcs)
3
000300
1.5V AAA batteries (1 pcs)
Ordering information:
All handy photometers
are supplied in a carton box including
2 cuvets, 6 reagents, 1 x 1.5 V AAA battery and instructions.
Low cost digital photometers to measure
Phosphate,Iron & Iodine
Iron is naturally present in water sup-
plies and therefore needs to be mon-
itored both in potable and industrial
applications. Milwaukee offers the
MW14 Iron meter with a range of
0.00 to 5.00 mg/L.
Phosphates are present in natu-
ral waters and at concentrations
typically found, do not pose any
specific health threats to humans.
However, excessive contamination of
water courses from agricultural fertilizer
run off or wastewater/effluent discharge
can promote excessive algae or plant
growth. Milwaukee offers MW12 with a range
of 0.00 to 2.50 mg/L.
Iodine is used as disinfectant in various
applications - one of the most common is the
poultry industry waste water treatment.
Milwaukee offers MW13 with a range of 0.0
to 12.5 mg/L.