User`s manual

System configuration Overall configuration
3 – 2
Following figure shows the system configuration for a Q00CPU, Q01CPU, Q00UCPU or
Q01UCPU (all without slots for a memory card).
Fig. 3-2: System configuration for Q00CPU, Q01CPU, Q00UCPU and Q01UCPU
QH00074C
NOTES It is only possible to mount the redundant power supplies Q63RP and Q64RP on a main
base unit of type Q38RB and Q68RB. Each base unit has two slots for redundant power sup-
plies.
The slim type main base units Q32SB, Q33SB and Q35SB can’t be connected to extension
base unit.
MITS UBISHI
LI
THIUM BATTERY
Battery
(Q6BAT)
Main base units
(Q33SB, Q35SB, Q38SB,
Q33B, Q35B, Q38B, Q312B,
Q38DB, Q312DB, Q38RB)
Connection cable
(QC05B, QC06B, QC12B,
QC30B, QC50B, QC100B)
Extension base unit
(Q63B, Q65B, Q68B, Q68RB
or Q612B)
Power supply module, I/O
module and Special function
module of MELSEC System Q
Q-CPU:
Q00, Q01, Q00U, Q01U
Extension base unit
Q52B or Q55B
Power supply module, I/O
module and Special function
module of MELSEC System Q
I/O module and Special
function module of MELSEC
System Q