Assembly Instructions
6
Natural gas conversion must be performed only by natural gas provider or service company.
1. Disconnect the propane hose from the gas valve (see Figure 8).
2. Unscrew and disconnect the propane orifice from the bellows (see Figure 9). Propane orifice (dia2.21mm
size) is painted with red mark.
Figure 9
Figure 8
NATURAL GAS CONVERSION
STOP
STOP
3. Replace the propane orifice with the natural gas orifice, screw the natural gas orifice with the bellows tightly,
then connect and tighten the natural gas orifice with inlet tube (see Figure 10). Natural gas orifice (E)
(dia4.18mm size) is painted with black mark.
Figure 10
gas valve
propane hose
propane orifice
bellows
propane orifice
bellows
inlet tube
bellows
natural gas orifice (E)