Assembly Instructions
 9 
To perform a leak test: 
1. Make 2~3 oz. of leak solution by mixing one part liquid dishwashing detergent and three parts water. 
 Noted: make sure control knob is “OFF”. 
2.  Apply several drops of solution where the cylinder attaches to regulator (see Figure 15), inspect the solution 
at the connection looking for bubbles. If NO bubbles appear, the connection is secure. If bubbles appear, the 
connection has the leak, disconnect the regulator, reconnect, perform another leak check. If you continue to 
see bubbles after several attempts, cylinder valve is defective and should be returned to cylinder’s supplier. 
3.  Apply several drops of solution where gas valve attaches to bellows (see Figure 16), where gas valve 
 attaches to hose (see Figure 17), and where inlet tube attaches to bellows (see Figure 18). If NO bubbles 
 appear, the connections are secure. If bubbles appear, the connection has the leak, disconnect, reconnect, 
 perform another leak check. If you continue to see bubbles after several attempts, the part is defective and 
 should replace the part. 
inlet tube-bellows connection (Figure 18) 
gas valve-hose connection (Figure 17) 
LIGHTING INSTRUCTIONS 
1.  Push in gas control knob slightly and turn to “OFF”. 
2.  Turn gas control knob the “ON/MIN”. 
3.  Push in gas control knob all the way and hold. Continue to press the ignition button for 15 seconds. 
4.  If the burner does not light in 15 seconds, release the knob and it will pop back out. Wait 5 minutes before 
attempting to light the burner again, repeat step 1 to 3. 
1. Push in gas control knob slightly and turn to “OFF”. 
WARNING: For your safety, read and follow the Lighting Instructions in this manual and in the Rating Plate on 
the appliance. IMPROPER LIGHTING PROCEDURES COULD RESULT IN A FIRE HAZARD OR EXPLOSION 
HAZARD OR PROPERTY DAMAGE, INJURY OR LOSS OF LIFE.
TO TURN OFF GAS 
ignition button
gas control knob
Figure 19
LIGHTING INSTRUCTIONS 
1. Push in gas control knob slightly and
2. Turn gas control knob to “ON/MIN”.
3. Push in gas control knob all the way
4. If the burner does not light in 15
1. Push in gas control knob slightly and turn to “OFF”.
TO TURN OFF GAS 
INSTRUCCIONES DE ENCENDIDO
PARA CERRAR EL GAS
1. Presione ligeramente la perilla de control del gas y gírela a la
2. Gire la perilla de control del gas a “ENC/MÍN” (encendido/mínimo).
3. Presione la perilla de control del gas hasta el fondo y mantenga presionada.
4. Si el quemador no se enciende en 15 segundos, suelte la perilla y esta
encender el quemador nuevamente, repita los pasos 1 al 3.
1. Presion ligeramente la perilla de control del gas y gírela a la
turn to “OFF”. 
and hold. Continue to press the
ignition button for 15 seconds.
seconds, release the knob and it will
pop back out. Wait 5 minutes before attempting
to light the burner again, repeat step 1 to 3. 
posición “APG” (apagado).
Siga presionando el botón de encendido durante 15 segundos.
volverá a su posición hacia afuera. Espere 5 minutos antes de intentar
posición “APG” (apagado)
OFF
(APG.)
MAX
(MÁX.)
1 AAA
1.5V
IGNITOR
( Encendedor )
ON/MIN
(ENC./MÍN.)