Datasheet

1 / 9
290 Avenue de Colmar BP 101
67024 STRASBOURG CEDEX1
Control and Signalling Units
Control and Signalling UnitsControl and Signalling Units
Control and Signalling Units
S
SS
SUMMARY
UMMARYUMMARY
UMMARY
PAGES
1. Description, use................................... 1
2. Range ................................................. 1
3. Measurement ...................................... 2
4. Installation........................................... 6
5. Technical characteristics ..................... 7
6. Compliance and approvals .................. 9
7. Equipment and Accessories ................ 9
1.
1. 1.
1. DESCRIPT
DESCRIPTDESCRIPT
DESCRIPTION
ION ION
ION -
--
- U
U U
USE
SESE
SE
Contact Block and illuminated block to be used with control unit
2.
2. 2.
2. RANGE
RANGERANGE
RANGE
(
((
(Alternative order code
Alternative order codeAlternative order code
Alternative order code)
))
)
. Refe
. Refe. Refe
. References
rencesrences
rences
33E01 33E10 33E11 33E10Y7 33E01Y7 33EAWL 33EARL 33EAGL
33EABL 33EAYL 33EAWL4 33EARL4 33EAGL4 33EABL4 33EAYL4
33EAWM 33EARM 33EAGM 33EABM 33EAYM 33EAWH 33EARH
33EAGH 33EABH 33EAYH 33ET 33ETT 33EFM 33EFH 33EHC 33ELC
LM11 331E10 331E01 333E01 333E10 333E02 333E20 333E11
333E21 333E12 333E03 334EAWL22 334EARL22 334EAGL22
334EABL22 334EAYL22 334EAWM22 334EARM22 334EAGM22
334EABM22 334EAYH22 334EAWH22 334EARH22 334EAGH22
334EABH22 334EAYH22 333EAWL10 333EARL10 333EAGL10
333EAWL11 333EARL11 333EAGL11 333EAWL20 333EARL20
333EAGL20 333EAWH10 333EARH10 333EAGH10 333EAWH11
333EARH11 333EAGH11 333EAWH20 333EARH20 333EAGH20 33D01
33D10 331ED01 331ED10 33R01 33R10 33EAWL 33RARL 33RAGL
33RABL 33RAYL 33EAWM 33RARM 33RAGM 33RABM 33RAYM
33EAWH 33RARH 33RAGH 33RABH 33RAYH 33RFM 33RFH 331ER01
331ER10 333ER20 333ER01 333ER11 333ER02 331ERAWL 331ERARL
331ERAGL 331ERABL 331ERAYL 331ERAWM 331ERARM 331ERAGM
331ERABM 331ERAYM 331ERAWH 331ERARH 331ERAGH 331ERABH
331ERAYH 333EP02 333EP20 33PAWL 33PARL 33PAWL 33PAYL
33P01 33P10 33P01Y7 33P10Y7 33S01 33S10 33SAWL 33SARL
33SAGL 33SABL 33SAYL 33SAWM 33SARM 33SAGM 33SABM
33SAYM 33SAWH 33SARH 33SAGH 33SABH 33SAYH 33E01C
.
. .
. Type of use
Type of useType of use
Type of use
. Contact Block
. LED Module
. Joystick Block
. Lamp-test Block
. Transformer Block
. Filter Block
.
. .
. Connection
ConnectionConnection
Connection
. Screw terminals
. Plug-In terminals
. Faston terminals
. Pin style terminals
2.
2. 2.
2. RANGE
RANGERANGE
RANGE
.
. .
. Mounting
MountingMounting
Mounting
. Front mounting with a clip
. Base mounting (control station)
.
. .
. Electrical Rating
Electrical RatingElectrical Rating
Electrical Rating
(Standard IEC 60947-5-1 – max rating ,
see page 6)
.
. .
. For screw terminals and plug
For screw terminals and plugFor screw terminals and plug
For screw terminals and plug-
--
-in terminals
in terminalsin terminals
in terminals
:
::
:
. Alternating current (AC-15): 120 V ≤ Ue ≤ 600 V
6 A ≥ Ie ≥ 1,2 A
. Direct current (DC-13): 125 V ≤ Ue ≤ 600 V
0,55 A ≥ Ie ≥ 0,1 A
.
. .
. For Pin style connection
For Pin style connectionFor Pin style connection
For Pin style connection
:
::
:
. Alternating current (AC-15): 120 V ≤ Ue ≤ 240 V
3 A ≥ Ie ≥ 1,5 A
. Direct current (DC-13): 125 V ≤ Ue ≤ 250 V
0,22 A ≥ Ie ≥ 0,1 A
.
. .
. For Faston terminals
For Faston terminalsFor Faston terminals
For Faston terminals
:
::
:
. Alternating current (AC-15): 120 V ≤ Ue ≤ 240 V
6 A ≥ Ie ≥ 3 A
. Direct current (DC-13): 125 V ≤ Ue ≤ 250 V
0,55 A ≥ Ie ≥ 0,27 A
. For LED
. For LED . For LED
. For LED Block
BlockBlock
Blocks
ss
s:
::
:
. 12 to 24 V AC/DC ±10%
. 48 V AC/DC ±10%
. 130 V AC – 8% / +15%
. 230 V AC ±15%
.
. .
. Minimum operating current
Minimum operating currentMinimum operating current
Minimum operating current
:
::
:
. Standard blocks (screws, plug-in, faston, pin style terminals)
. Ue= 24 V DC and Ie= 5mA
. Low level contact blocks (screws, pin style)
. Ue= 5 V DC and Ie= 1 mA
Creation date: 22/10/07 Update : 22/10/07

Summary of content (10 pages)