Datasheet

8 / 9
Refe
RefeRefe
Reference(s)
rence(s)rence(s)
rence(s)
:
::
:
See range
See range See range
See range section
sectionsection
section
5
55
5.
. .
. TECHNICALS CHARACTERISTICS
TECHNICALS CHARACTERISTICSTECHNICALS CHARACTERISTICS
TECHNICALS CHARACTERISTICS
. For joystick blocks
. AC15 (Alternating current)
- Ue = 60 V Ie = 10 A
- Ue = 110 V Ie = 6 A
- Ue = 220 V Ie = 3 A
- Ue = 380 V Ie = 2 A
- Ue = 500 V Ie = 1,5 A
- Ue = 600 V Ie = 1,2 A
. DC13 (Direct current)
- Ue = 24 V Ie = 2,5 A
- Ue = 48 V Ie = 1,4 A
- Ue = 60 V Ie = 1 A
- Ue = 110 V Ie = 0,55 A
- Ue = 220 V Ie = 0,27 A
- Ue = 300 V Ie = 0,2 A
Conventional thermal current in enclosure
Conventional thermal current in enclosureConventional thermal current in enclosure
Conventional thermal current in enclosure
:
::
:
. For standards blocks (screw or Plug-in terminals)
. Ith = 16 A in AC
. Ith = 2,5 A in DC
. For Faston terminals blocks
. Ith = 10 A in AC
. Ith = 2,5 A in DC
. For Pin style terminal blocks
. Ith = 5 A in AC
. Ith = 1 A in DC
Rated insulation voltage
Rated insulation voltageRated insulation voltage
Rated insulation voltage
:
::
:
. For screw terminal contact blocks
. Ui = 690 V according to IEC 60947-5-1
. Ui = 600 V according to UL508
. For faston terminal blocks
. Ui = 320 V according to IEC 60947-5-1
. Ui = 300 V according to UL 508
. For LED blocks
. Ui = 300 V according to IEC 60947-5-1
. For Pin-style terminal blocks
. Ui = 250 V according to IEC 60947-5-1
Pollution degree
Pollution degreePollution degree
Pollution degree
:
::
:
. 3
Rated impulse withstanding voltage
Rated impulse withstanding voltage Rated impulse withstanding voltage
Rated impulse withstanding voltage
:
::
:
. For standard contact and faston blocks
. Uimp = 6kV according to IEC 60947-5-1
. For LED and Pin-style terminal blocks
. Uimp = 4kV according to IEC 60947-5-1
L
LL
LED
ED ED
ED blocks
blocksblocks
blocks
:
::
:
. Life time:
- red and yellow 100 000 hours at 25°C under Un
- others colours 50 000 hours at 25°C under Un
. LED power consumption:
. For 24 V = 20 mA
. For 48 V = 15 mA
. For 130 V = 20 mA
. For 230 V = 16 mA
5
55
5.
. .
. TECHNIC
TECHNICTECHNIC
TECHNICAL CHARACTERISTICS
AL CHARACTERISTICSAL CHARACTERISTICS
AL CHARACTERISTICS
. Operating voltage : 12, 24, 48, 130, 230 V
. Frequency: 50 or 60 Hz
. Electromagnetic compatibility :
. Electrostatic discharge immunity test according test IEC
61000-4-2 level 2
. Radiated, radio-frequency, electromagnetic field immunity test
according to IEC 61000-4-3 level 3
. Electrical fast transient/burst immunity test according to IEC
61000-4-4 :
. Level 2 for Un = 24 to 48 V
. Level 3 for Un = 110 to 230 V
. Surge immunity test 1,2 / 50 μs according to IEC 61000-4-5 :
. Level 2 for Un = 24 to 48 V
. Level 3 for Un = 110 to 230 V
. Immunity to conducted disturbances, induced by radio-
frequency fields according to IEC 61000-4-6
. Voltage dips, short interruptions and voltage variation immunity
tests according to IEC 61000-4-11 only on models Un = 100 to
230V
Protection Fuse
Protection FuseProtection Fuse
Protection Fuse
:
::
:
. For the standards blocks
. 10 A gG according to IEC 60947-5-1
. For pin-style terminals blocks
. 6 A gG according to IEC 60947-5-1
Mechanical life
Mechanical lifeMechanical life
Mechanical life
:
::
:
. For screw, Faston and pin-style terminals blocks
. 5 000 000 cycles
Electrical operating life
Electrical operating lifeElectrical operating life
Electrical operating life
:
::
:
. For screw, faston and pin-style terminal blocks
. 1 000 000 cycles:
- AC15 – B300
. Ue = 120 V Ie = 3 A
. Ue = 240 V Ie = 1,5 A
- DC13 – R300
. Ue = 125 V Ie = 0,22 A
. Ue = 250 V Ie = 0,1 A
Operating Temperature
Operating TemperatureOperating Temperature
Operating Temperature
:
::
:
. minimum : -25°C maximum : +70°C
Creation date: 22/10/07 Update : 22/10/07