Datasheet

96
Technical characteristics
Characteristics
Standards
Data
>
Rated insulation voltage
300 V IEC 60947-5-1
>
Rated impulse voltage Uimp 4 kV (with filter block see p. 64)
IEC 60947-1
Pollution degree 3
>
Operating voltage
12
to
24 V
AC/DC
48 V AC/DC (for LED block)
130 V
AC
230 V
AC
>
Frequency 50 or 60 Hz
>
Lifetime at rated supply voltage Red and yellow:
100 000
hours at
25 °C
Other colours:
50 000
hours at
25 °C
>
Consumption of LED blocks Voltage:
- 24 V: 25
m
A ± 20%
- 48 V: 15
m
A ± 5%
- 130 V: 20
m
A ± 10%
- 230 V: 16
m
A ± 30%
LED BLOCKS FOR ILLUMINATED HEADS AND ONE PIECE LED PILOT LIGHTS
>
CONTACT BLOCKS
>
Pin-style connection (for PCB)
Standards
Data
>
Rated insulation voltage
250 V
AC
IEC 60947-1
250 V
AC
UL 508
>
NC contacts Positive opening
IEC 60947-5-1
>
Rated impulse withstanding voltage Uimp 4 kV
Pollution degree 3
>
Conventional thermal current in free air conditions
AC 15: 5 A IEC 60947-5-1
DC 13: 1 A
>
Electrical ratings Alternating current Direct current
IEC 60947-5-1
AC 15 - B 300 DC13 - R 300
Ue = 120 V,Ie=3A Ue=125V,Ie=0,22A
IEC 60947-5-4
Ue=240V,Ie=1,5A Ue=250V,Ie=0,1A
Minimum current of use
- standard blocks - golden contacts
Ue=24VDCandIe=5mA Ue=5VDCandIe=1mA
Failure rate < 10
-8
Failure rate < 10
-8
>
Electrical operating life 1 million cycles for:
- AC15 - B 300 - DC13 - R 300
Ue = 120 V, Ie = 3 A Ue = 125 V, Ie = 0,22 A
Ue=240V,Ie=1,5A Ue=250V,Ie=0,1A
>
Pin diameter ø 1 mm
BACO_081-096_GB.qxd 28/11/12 12:06 Page 96