User's Manual
Installation Data
IDENTIFICATION
Each ORION pit endpoint can be identied using the unique numeric serial number located on a tag attached to the wire har-
ness. Each Badger Meter encoder is clearly identied on the face of the register with an assembly number, unit of measure
and meter model.
Recordall Transmitter
Register (RTR
®
)
Absolute Digital
Encoder (ADE
®
)
Figure 1: Encoders
ORION INSTALLATION KITS
TYPE DESCRIPTION PART NUMBER
PIT
Through Lid Installation Kit 64394-001
Below Lid with Knuckles 64394-003
Armorcast Installation Kit 64394-009
VAULT
Vault Installation Kit/Non-Standard
Permalog+
®
64394-008
REMOTE
Remote Box Enclosure 64394-021
Remote Bracket Kit (RTR) 64394-019
Remote Bracket Kit (ADE) 64394-020
UNPACKING
Carefully remove the pre-wired ORION endpoint and encoder from the shipping carton and inspect the assembly for dam-
age. Retain the contents of the installation kit for use in mounting the endpoint in the eld.
The ORION endpoint (see Figure 2) can be shipped pre-wired to the Badger Meter encoder. When the factory pre-wired,
there is no splicing required and only the mounting of the encoder with tightening of the TORX® seal screw is necessary.
When installing, excess wire should be coiled and cable tied to avoid any damage.
NETWORK Endpoint INSTALLATION
Badger Meter recommends that when installing an endpoint in a pit, the endpoint must be mounted either through or under
the lid of a non-metal pit lid for ecient propagation of the radio signal. If the endpoint is being installed indoors, a wired
radio endpoint should be mounted on the outside of the building or in the oor joist near the outside wall of the building,
and away from large metal objects for ecient propagation of the radio signal.
(12-10)