ELECTRICAL / NETWORK INSTALLATIONS
Access to Power and Use of a NEMA 4 Enclosure
• The ORION SE network gateway transceiver requires access to power and can use either a 120V AC grounded outlet
for use with the AC-to-DC power supply and power cord (66528-002) or a DC power source to be used with the DC
power source cable with 308 in-line connector (Figure 14).
• Use of NEMA 4 enclosure, or equivalent.
• AC-to-DC power supply used outdoors or in a non-environmentally controlled indoor location requires a
customer-supplied NEMA 4 enclosure, or equivalent, installed in accordance with appropriate electrical codes,
building codes, industry codes, regulations and standards.
• Consult the appropriate electrical, building and industry codes, regulations and standards for accepted
installation practices for use of the AC-to-DC power supply and outlet in environmentally controlled indoor
locations.
• Outlet and enclosure (if required) should be mounted for easy accessibility by authorized utility personnel at the
installation site.
GPRS and Wi-Fi Recommended Installation
AC to DC Power Supply with
308 In-line Connector End and
Power Cord (supplied)
120VAC
Grounded Outlet
(customer
supplied)
Power Supply Cable with
308 In-line Connector
ORION SE Power Cable with
308 In-line Connector
(supplied)
Figure 14: GPRS / Wi-Fi Connections (*Shown with NEMA 4 enclosure.)
*An enclosure may be recommended but is not included.
If NEMA 4 enclosure or equivalent is required, the minimum enclosure size is 12 inch x 10 inch x 6 inch (H x W x D).