Network Endpoint Installation
When installing an SE or ME (used with a network gateway transceiver) or CE (used with an ORION 4.0 or 2.0 gateway
receiver) endpoint in a pit, the endpoint must be mounted through the lid of a non-metal pit lid for maximum propagation
of the radio signal. If the endpoint is being installed indoors, a wired radio endpoint should be mounted on the outside
of the building or in the oor joist near the outside wall of the building, and away from large metal objects for maximum
propagation of the radio signal.
Splicing Considerations
For non-submerged indoor and outdoor applications where splicing is necessary, splice connections together and wrap any
cables inside the base of the housing.
Splice connections made in pit environments require a pit eld splice kit (62084-001), which can be ordered separately.
Please refer to RTR-I-15 for eld splice kit installation instructions.
ORION endpoints shipped factory pre-wired to a Badger Meter encoder require no splicing. Only the mounting of the
encoder to the meter and tightening the TORX® seal screw is necessary.
For all installations, excess wire should be coiled and cable tied to avoid any damage.
ORION Installation Kit Part Numbers*
TYPE DESCRIPTION ORION SE ORION ME ORION CE
PIT
Through the Lid Installation Kit 64394-024 64394-024 64394-001
Below Lid with Knuckles
Installation Kit
64394-025 64394-003
Integrated Pit Lid Hanger
Installation Kit
64394-026 64394-009
VAULT
Vault Installation Kit/Non-Standard
Permalog+
®
Installation Kit
64394-027 64394-008
REMOTE
Remote Wall Mount Box Enclosure Kit 64394-028 64394-028 64394-021
Remote Installation Bracket Kit 64394-029 64394-029 64394-019
* Refer to ORI-P-09 for individual endpoint installation kit components.