4. Strip the ends of the six (6) colored wires to a length of 1/8 inch. Twist the conductors on each wire.
5. Shorten the drain/bare wire (no insulation) to 11/16 inch.
6. Loosen each screw (about 2…3 turns) on the female insert and attach the wires to the female insert using the chart
below. Retighten each screw after the wire has been connected.
BE CAREFUL NOT TO BACK THE SCREWS OUT TOO FAR. THE SCREWS ARE SMALL AND CAN EASILY BE LOST IF
THEY ARE DROPPED.
Wire Female insert connector
Slot
Red
1
2
3
4
5
7
8
Brown
Black
White
Green
8 (center) is for the shield-drain
M12 Connector Wire Contact View
Blue
White 4
Drain 8 (Center)
Black 3
Blue 7
Red 1
Green 5
Brown 2
7. Assemble the female insert to the coupling sleeve by aligning the female insert tab slot with the notch in the
coupling sleeve.
Figure 24: Slot alignment
Female Insert
Tab Slot
Coupling Sleeve Insert
Notch