Data Sheet
Turbine meter
Vision Series 3000
TUR_VIS_3000_DB_02_2259 (March 2020)
Data sheet
DESCRIPTION
The small turbine meter VISION measurement technology is
ideal for the accurate measurement of low viscous and non-
aggressive fluids. The VISION 3000 series is most suited for
the measurement of flow rates from 5 to 65 l/min. The
turbine meters can be mounted in any position.
MEASURING PRINCIPLE
Turbine meters are indirect volumetric meters. When the
fluid passes through, a rotor is activated and the movement
is either electronically or mechanically transmitted outside.
The rotor is turned by the fluid force, proportional to the flow
rate. A Hall effect sensor detects the passage of the rotor and
supplies pulses, which can be utilized for digital or analogue
signal processing. The generated pulses are specified as the
K-factor. The large number of pulses provides high
resolution. As the mass of the turbine is very small the
response time is very short. It is not necessary to install a
straight length of pipeline at the upstream side of the meter.
SPECIFICATIONS
Type
VISION 3012
Performance
Flow rate
5 – 65 l/min
Accuracy
± 3% of reading
Repeatability
< 0.5% under the same operating conditions
Operating temperature
-20°C to 100°C
Operating pressure rate
max. 25 bar
Burst pressure
200 bar
Pick up
Pulse sensor
Hallsensor
Input power
5 – 24 VDC
Output signal
Open collector (NPN sinking) @ max. 20 mA, 1-2.2 kOhm pull up resistor required
Power consumption
approx. 8 mA
K-factor Version Material Nominal size Flow range K-factor
VISION 3012 Trogamid CX7323 12 mm 5 – 65 l/min 210 pulse/liter