DESCRIPTION
The small turbine meter VISION measurement technology is
ideal for the accurate measurement of low viscous and non-
aggressive fluids. The VISION 2000 series is most suited for
the measurement of flow rates from 0.5 to 35 l/min. The
turbine meters can be mounted in any position.
MEASURING PRINCIPLE
Turbine meters are indirect volumetric meters. When the
fluid passes through, a rotor is activated and the movement
is either electronically or mechanically transmitted outside.
The rotor is turned by the fluid force, proportional to the flow
rate. A coil detects the passage of the rotor and supplies
pulses, which can be utilized for digital or analogue signal
processing. The generated pulses are specified as the K-
factor. The large number of pulses provides high resolution.
As the mass of the turbine is very small the response time is
very short. It is not necessary to install a straight length of
pipeline at the upstream side of the meter.
SPECIFICATIONS
Type
VISION 2006 - COIL
VISION 2008 - COIL
Performance
Flow rate
0.5 – 35 l/min
Accuracy
± 3% of reading
Repeatability
< 0.5% under the same operating conditions
Operating temperature
-20°C to 100°C
Operating pressure rate
max. 25 bar
Burst pressure
200 bar
Pick up
Pulse sensor
COIL (battery powered)
Input power
2 – 5.5 V
Output signal
Push-Pull
Power consumption
approx. 2.2 μA @ 2V
K-factor Version Material Nominal size Flow range K-factor
VISION 2008 4F17-COIL Trogamid CX7323 8 mm 2 – 35 l/min 750 pulse/liter
VISION 2008 4F22-COIL Trogamid CX7323 8 mm 1 – 25 l/min 1000 pulse/liter
VISION 2008 4F44-COIL Trogamid CX7323 8 mm 1 – 15 l/min 2200 pulse/liter
VISION 2006 4F44-COIL Trogamid CX7323 6 mm 1 – 10 l/min 3300 pulse/liter
VISION 2008 2F66-COIL Trogamid CX7323 8 mm 0.5 – 7.5 l/min 4700 pulse/liter
VISION 2006 2F66-COIL Trogamid CX7323 6 mm 0.5 – 5 l/min 6900 pulse/liter