Turbine meter type Vision 1000
Wiring and installation
Electrical connection plan
Output signal
The output signal is square wave signal where the frequency is
proportional to the flow rate. An external, user-supplied pull-
up resistor is required to ensure that the open collector will
sink less than 20 mA. Applying a current greater than 20 mA
may damage the sensor.
Operating and Installation instructions
1. Check compatibility of media with sensor material
Trogamid.
2. Solid ingredients in medium require a filter in front of
a sensor. Avoid absolutely fibrous soiling.
3. Install sensor into properly cleaned pipeline only.
4. Check electrical connection according to the electrical
wiring plan.
5. Do not exceed the specific indications.
6. The Vision 1000 is a volumetric measuring device, i.e.
air/gas in liquid will be included in measured volume.
7. Correctly installed, the sensor works entirely
maintenance free.
8. The Vision
1000 is not for general public use and is to
be installed and applied by trained personnel only.
9. Do not blow out the turbine with compressed air. This
may damage the bearings.
With DIN connector
Function DIN termination
V+ 1
-
Output 2