Data Sheet
Turbine meter
Vision Series 1000 battery powered
TUR_VIS_1000-COIL_DB_02_2256 (January 2021)
Data sheet
DESCRIPTION
The small turbine meter VISION measurement technology is
ideal for the accurate measurement of low viscous and non-
aggressive fluids. The VISION 1000 series is most suited for
the measurement of flow rates from 0,1 to 2,5 l/min. The
turbine meters can be mounted in any position.
MEASURING PRINCIPLE
Turbine meters are indirect volumetric meters. When the
fluid passes through, a rotor is activated and the movement
is either electronically or mechanically transmitted outside.
The rotor is turned by the fluid force, proportional to the flow
rate. A coil detects the passage of the rotor and supplies
pulses, which can be utilized for digital or analogue signal
processing. The generated pulses are specified as the K-
factor. The large number of pulses provides high resolution.
As the mass of the turbine is very small the response time is
very short. It is not necessary to install a straight length of
pipeline at the upstream side of the meter.
SPECIFICATIONS
Type
VISION 1005 2F66 - COIL
Performance
Flow rate
0.1 – 2.5 l/min
Accuracy
± 3% of reading
Repeatability
< 0.5% under the same operating conditions
Operating temperature
-20°C to 100°C
Operating pressure rate
max. 25 bar
Burst pressure
~ 200 bar
Pick up
Pulse sensor
COIL (battery powered)
Input power
2 – 5.5 V
Output signal
Push-Pull
Output current
max. 30 mA
Power consumption
~ 2.2 μA @2V
K-factor Material Nominal size Flow range K-factor
Trogamid CX7323 5 mm 0.1 – 2.5 l/min 22000 pulse/liter
Stainless steel, INOX 1.4401 / AISI 316 5 mm 0.1 – 2.5 l/min 24500 pulse/liter