Register output specifications & wiring Page 15/16
AC_ILR_BA_02_1610
5.5. Pulse and analog output (model ILR750 and 750T)
Register wiring
External DC+ : Yellow
External ground : Brown
Pulse output : White
Analog output : Green
DC input : 8 to 24 VDC; 20 to 40mA
Outputs:
- Analog 4 to 20mA output in loop powered configuration; external load of 50 ohms to 250
ohms; flow rate is linear scaled between 4mA minimum and 20mA maximum set points;
flow rates below programmed minimum read 4mA.
- Pulse output with internal pull-up resistor; optional open collector output with output
jumper removal; pulse output is scalable in pulses per liter or pulses per gallon.