1. Press the RESET button to toggle between available options (“I, for an inline-to-
flow orientation and “P” for a perpendicular-to-flow orientation or “O” for Remote
versions and for the RCDL-nutating disc meters and the Vision turbine meters).
2. When finished adjusting the register orientation, press and hold the TOTAL button
for one second to advance to the “Default Display” section.
3.5. Changing the display mode (for all ILR models with display)
The display mode screen (indicated by a “d” on the top row, on the left side) determines
the information displayed on the top line of the register during normal operation. The
display mode may be either the totalizer screen or the flow rate screen.
“C,” indicates the totalizer screen and “F” indicates the flow rate screen. The totalizer
screen is depicted below:
Figure 8: Default display
1. While a letter is flashing on the display, press the RESET button to select either
totalizer or flow rate.
2. Upon completion of this setting, the programming of the industrial standard register
and the industrial dual pulse output is complete. For ILR 710, ILR730, ILR701,
ILR701T, ILR750 and ILR750T models, see additional programming parameters.
3.6. Exiting programming mode (for all ILR models with display)
To exit the programing mode:
1. On any screen, press and hold the both the TOTAL and RESET buttons. The
screen will revert back to the programmed scale factor, and then flash.
Following the three flashes, the register display will be blank.
Note: Pressing the TOTAL or RESET buttons will turn the display back on.