3.3. Changing the meter pulse rate (for all ILR models with display)
The meter pulse rate (screen is indicated by the “I” on the top row, on the left side) is the
number of pulses per unit of measure as detected by the register. The pulse rate varies
according to the type of attached meter. The bottom row consists of the 5-digit integer
value of the meter pulse rate, whereas the top row consists of the 2-digit decimal value of
the meter pulse rate.
The meter pulse rate is entered in pulses per liter if the selected unit of measure is liters.
The meter pulse rate is entered in pulses per gallon if the selected unit of measure is
gallons, quarts or pints.
Figure 6: Meter Pulse Rate
1. Press the TOTAL button to select a digit (selected digits flash). Press RESET to
change the selected digit. The pulse rate can be any value between 00000.01 and
99999.99 on the top row; integer values are displayed on the bottom row.
Example: 10.45 would display .45 on the top row and 10 would be displayed on the
bottom row.
2. When finished adjusting the pulse rate, press and hold the TOTAL button for one
second to advance to the “register orientation” section.
NOTE: Error checking will not allow the user to advance to the next screen.
3.4. Changing the register orientation (for all ILR models with display)
For oval gear meters: Depending on the orientation perpendicular or inline on the meter.
For remote version, this will be set to “o”.
For nutating disc meters (RCDL) set to “O”.
For turbine meters (Vision) set to “o”.
Figure 7: Register orientation
Flow
direction
Inline
Perpendicular