User's Manual

13
Step 6: Tighten all screws evenly with a large
screwdriver to approximately 70 inch-lbs.
Program the Badger ORION Transmitter
Badger
®
uses the Radix
®
system to display
and process screens.
Place the Radix so the optic read head aligns
with the LED output port. The angle of
approach should be about 30 degrees.
Radix
Rotate Radix unit to
about a 30 degree
angle
30°
4
3
Step 5: Use four (4) 18-18x3-1/2 supplied
mounting screws and a washer on each to
attach the index, cover plate, and Badger
®
ORION transmitter to the gas meter.
Washer
Step 3: Be sure the gas INLET markings are
on the same side of the meter and the lens
faces forward.
Gas INLET
markings
Lens facing
forward
Step 4: Place the American
®
Index and cover
plate (removed earlier) back on the
Badger
®
ORION
®
transmitter.
Place it so the text;
TURBINE FRONT FLOW
AL-600, AL-1000, AL-1400, AL-2300, and
AL-5000
(or other such text); faces the front and
the top hole is centered around the upper
drive pawl.
Place the index drive
pawl perpendicular to
the transmitter drive
pawl.