User's Manual

8
2 foot dial
Transmitter
Moving the
two foot dials
Index on XMTR
Step 3: Secure the index to the transmitter
with the two (2) supplied Phillips screws
placed in the stand offs.
Step 4: Mount the gasket to the meter.
Step 4: Remove and discard old gasket.
Step 3: Use a screwdriver to remove and
discard the two (2) index mounting screws.
Install ORION
®
Transmitter and Sensus
Index on Meter
Use care when handling the ORION
transmitter to insure the drive pawl is not
subjected to any physical abuse. Abuse may
cause this spindle to become bent,
misaligned or otherwise inoperative.
When attaching a meter index to an ORION
transmitter, make sure it mounts securely. The
two drive gears must mate without causing
any binding or potential for disengagement.
Step 1: Place the two (2) supplied stand offs
in the transmitter.
Stand Offs
Step 2: Place the index on the front of the
ORION transmitter.
Line up two front gears. Test to ensure the
gears are engaged and moving freely by
moving the 2 foot dial.
2 Screws
2 Stand Offs
2 foot dial
Gears aligned
Transmitter
Moving the
two foot dial