Installation Manual
TOOLS AND MATERIAL
BadgerTouch® Remote Module with Installation Kit
63705-004
Suggested Tools
• Electric drill
• 3/16 in. carbide tip masonry drills
• 1/4 in. drill bit for anchor screws
• Blade and Phillips screwdrivers
• T-25 wire stapler and staples
• Touch reading device for installation verification
Application includes:
• (1) BadgerTouch Module assembly
• (2) 55211-231 screw, Phillips head
• (2) 62359-001 screw, anchor 10-12 (1/4 in. drill bit required)
• (2) 34776-001 cable tie
Optional Material
56088 GE RTV-162 Adhesive Sealant
APPLICATION
Coupled with the E-Series® Ultrasonic meter or the Badger Meter
High Resolution Encoder (HR-E®), the BadgerTouch® Remote Module
is a complete electronically encoded close-proximity automated
meter reading system, specifically designed for single point remote
meter installations. BadgerTouch Remote Modules are supplied as
standalone modules for field connection to an E-Series® Ultrasonic
3 or 4 inch meter, or to an HR-E encoder with all Recordall® Disc,
Turbo, Compound, Combo, and Fire Series meters and assemblies.
Interrogation of the Remote Module displays the unique meter
serial number and the meter reading.
Figure 1: Remote Module
INSTALLATION
OTE: N Make sure to locate the corresponding Ultrasonic meter or
HR-E encoder (meter/encoder) for installation.
Unpacking
Carefully remove the BadgerTouch Remote Module (Figure 1) from
the shipping carton. Retain the contents of the installation kit for
connecting the meter/encoder.
Location
Choose an accessible outdoor location to install the BadgerTouch
Remote Module within the limits of the meter/encoder cable.
Remote Module Installation
Follow the steps in this section to:
• Connect the meter/encoder to the Remote Module.
• Mount the Remote Module. The Remote Module must be
securely mounted to a rigid surface. Avoid mounting on loose
siding of any type, as this may lead to wire breakage.
Figure 2: Remote Module connection
1. After choosing the location for installation, use the Remote
Module as a template to position the two mounting holes on
the outside of the building that houses the meter/encoder. The
Remote Module should be located within 75 feet maximum
wire distance of the meter/encoder using Belden 9770 wire.
Additional wire length and other wire types may
aect performance.
2. Drill a 3/16 inch wire entry hole in the building wall to
accommodate the meter/encoder cable. Cut the protective
gel cap o the end of the meter/encoder cable. Feed the cable
through the wall and then cut the cable to the proper length,
making sure you have sucient wire to make the connection to
the Remote Module.
BadgerTouch®
Automated Meter Reading System Remote Module
Model ESERIESBT and HREBT
BTA-UM-00232-EN-05 (January 2020)
Installation Manual
DRAFT