Installation Manual

TOOLS AND MATERIAL
BadgerTouch® Remote Module with Installation Kit
63705-004
Suggested Tools
Electric drill
3/16 in. carbide tip masonry drills
1/4 in. drill bit for anchor screws
Blade and Phillips screwdrivers
T-25 wire stapler and staples
Touch reading device for installation verification
Application includes:
(1) BadgerTouch Module assembly
(2) 55211-231 screw, Phillips head
(2) 62359-001 screw, anchor 10-12 (1/4 in. drill bit required)
(2) 34776-001 cable tie
Optional Material
56088 GE RTV-162 Adhesive Sealant
APPLICATION
Coupled with the E-Series® Ultrasonic meter or the Badger Meter
High Resolution Encoder (HR-E®), the BadgerTouch® Remote Module
is a complete electronically encoded close-proximity automated
meter reading system, specifically designed for single point remote
meter installations. BadgerTouch Remote Modules are supplied as
standalone modules for field connection to an E-Series® Ultrasonic
3 or 4 inch meter, or to an HR-E encoder with all Recordall® Disc,
Turbo, Compound, Combo, and Fire Series meters and assemblies.
Interrogation of the Remote Module displays the unique meter
serial number and the meter reading.
Figure 1: Remote Module
INSTALLATION
OTE: N Make sure to locate the corresponding Ultrasonic meter or
HR-E encoder (meter/encoder) for installation.
Unpacking
Carefully remove the BadgerTouch Remote Module (Figure 1) from
the shipping carton. Retain the contents of the installation kit for
connecting the meter/encoder.
Location
Choose an accessible outdoor location to install the BadgerTouch
Remote Module within the limits of the meter/encoder cable.
Remote Module Installation
Follow the steps in this section to:
Connect the meter/encoder to the Remote Module.
Mount the Remote Module. The Remote Module must be
securely mounted to a rigid surface. Avoid mounting on loose
siding of any type, as this may lead to wire breakage.
Figure 2: Remote Module connection
1. After choosing the location for installation, use the Remote
Module as a template to position the two mounting holes on
the outside of the building that houses the meter/encoder. The
Remote Module should be located within 75 feet maximum
wire distance of the meter/encoder using Belden 9770 wire.
Additional wire length and other wire types may
aect performance.
2. Drill a 3/16 inch wire entry hole in the building wall to
accommodate the meter/encoder cable. Cut the protective
gel cap o the end of the meter/encoder cable. Feed the cable
through the wall and then cut the cable to the proper length,
making sure you have sucient wire to make the connection to
the Remote Module.
BadgerTouch®
Automated Meter Reading System Remote Module
Model ESERIESBT and HREBT
BTA-UM-00232-EN-05 (January 2020)
Installation Manual
DRAFT