Manual
Form #04-VAM-UM-00229 09/12 Page 9
A 4-pin Brad Harrison® quick-
disconnect plug is available upon
special order.
4-Pin Connector used with
SPDT Micro Switch
Red Normally Closed (NC)
Black Normally Open (NO)
White Common
Green Ground
TABLE 3 4PIN CONNECTOR
MICRO SWITCH
WIRE DESIGNATIONS
NOTE: If the factory supplied cable
is removed for hard wiring the meter,
switches must be connected with
0.187” × 0.020” insulated ag termi-
nals designed for the appropriate wire
gauge for the application.
REED SWITCH MODELS
Safe operation of the reed switch is
dependent on not exceeding the
maximum wattage for that switch.
For example the normally open
reed switch has a maximum power
rating of 10 Watts. If the switch is
to operate at 24 VDC the maximum
current is found by dividing the
wattage by the voltage.
I =
W
E
=
10
24
= 0.417A
All meters (size ¼” to 1½”) are
oered in single (1) switch or
double (2) switch models and come
equipped with a 4-pin Hirschmann
connector. All units are quipped
with a 15’ length of 4-wire #22 AWG
type PVC jacketed cable.
4-Pin Connector used with
SPST Reed Switch
Red Switch 1 Contact
Black Switch 1 Contact
White Optional Switch 2 Contact
Green Optional Switch 2 Contact
TABLE 4 4PIN CONNECTOR
REED SWITCH
WIRE DESIGNATIONS
ALL MODELS
The strain relief connection on the
outside of the enclosure is water-
tight. Be sure to consult local wiring
codes before applying power. Some
installations will require rigid con-
duit. By removing the black strain
relief connections from the outside
of the enclosure, a conduit connec-
tion is accessible.