TROUBLESHOOTING
Dispense Keypad Error Messages
These error messages can be displayed by the Dispense Keypad. The associated action to reset the system is listed behind.
Message Messages at the Dispense Keypad
Hose active hit hose reset The selected meter currently has a dispense order in waiting to be processed, complete
the active order. Press RESET.
WO refused The entered work order number is not valid and has been refused by host or FMS software.
Master is down The master does not respond to a request from the Dispense Keypad
PC is down The FMS software (KPS) is not responding to the Master Keypad. Only if WO validation PC is
activated.
HOST is down The HOST (DMS) is not responding to the Master Keypad. Only if “WO Validation HOST is
activated. Press RESET.
Host or PC is occupied Master keypad is occupied by another job. Press RESET.
Wrong hose for fluid The meter selected is not a valid meter for the fluid assigned for this WO.
↑ ↓
RF communication is in progress, please wait (10 sec).
Meter Error Codes
The meter has several Error Codes that may display. These provide indication, at the meter, that there is an error in
communication between the meter and keypad.
Message Messages at the Meter
F01 The meter radio is not working.
To clear the error, press the RESET button on the meter.
F02 The meter is not configured to a keypad.
To clear the error code, press the RESET button on the meter.
Verify that the meter radio address is configured properly.
F03 System busy.
To clear the error, press the RESET button on the meter.
F08 Meter lost connection to network.
Out of range—network connection lost.
Keypad not powered.
Meter moved out of range of keypad.
F09 Meter not connected to a network.
First time being powered up.
Network selected is not available.
SF0
(Scale Factor 0)
The Scale Factor setting for the meter is set to 0.000.
To input a valid Scale Factor for the meter follow the instructions in the Change Factory Settings section
of this manual.
All other
Error Codes
Are for factory purposes only.
To clear the meter, press RESET.
Press RESET once more at the meter.