Fluid Management System Model FMS-3, 2.4 GHz Standalone Keypad IOM-208-01-EN (August 2012) 53400-208 Rev.
Fluid Management System Standalone Keypad Page ii August 2012
Installation & Operation Manual CONTENTS STANDALONE KEYPAD DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Disclaimer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Product Identification Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fluid Management System Standalone Keypad METER RESET (MET) MENU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 REPORTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 190 Menu (Internal Printer) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation & Operation Manual STANDALONE KEYPAD DESCRIPTION Disclaimer The user/purchaser is expected to read and understand the information provided in this manual, follow any listed Safety Precautions and Instructions and keep this manual with the equipment for future reference. The information in this manual has been carefully checked and is believed to be entirely reliable and consistent with the product described. However, no responsibility is assumed for inaccuracies, nor does Badger Meter Inc.
Fluid Management System Standalone Keypad Specifications Power Requirements 120V AC 50/60 Hz RF Communications 2-way, 2.4…2.5 GHz Direct Sequence Spread Spectrum RF Network Self-healing Mesh Network Operating Temperature 14…140° F (–10…60° C) Certification • • • • Contains FCC ID: S4GEM35XB Contains IC: 8735A-EM35XB FCC CERTIFIED, PART 15, SUB-PART C CE0681 EC-R&TTE Certified This device complies with Part 15 of the FCC Rules.
Installation & Operation Manual KEYPAD UP TO 30 RF METERS PER KEYPAD HOSE 1:1 WITH METER 10-W-30 10-W-40 GEAR TRANS OIL FLUID UP TO 8 FLUID TYPES AND 8 TANKS PER KEYPAD Figure 2: Setup Diagram August 2012 Page 7
Fluid Management System Standalone Keypad Standalone Keypad Keys The Scroll key selects options on the active display. The Home key returns the display to the default screen. The Backspace key deletes one character to the left of the cursor each time it is pressed. The Enter key completes the current action then displays the next screen. The Space key adds a blank space to the right of the data just entered. to Page 8 The Alphanumeric keys enter numbers and alpha characters (letters).
Installation & Operation Manual STANDALONE KEYPAD SCREEN TYPES The remainder of this document shows only the actual display, not the entire keypad. Default Screens The Default screens toggle between the System Version screen and the Enter PIN Number screen. The System Version screen displays for 2 seconds, then the Enter PIN Number screen displays for 3 seconds. The cycle repeats until a PIN number is entered. System Version 16aug2012 08:35 V3.00 2.4GHz The first default screen is informational.
Fluid Management System Standalone Keypad Multiple-Choice Screens Mileage Info YES / NO For Multiple-Choice screens, use the Scroll key to move the cursor to either YES or NO, then press Enter. Input Screens Tank Unit Tank No = Page 10 To enter or change information on the input screens, press the Backspace key to delete the current information, then use the keypad keys to type the new information, then press Enter to save the change.
Installation & Operation Manual INITIALIZATION (INI) MENU The Initialization screens appear in this order: • Time and Date • Tank Initialization • Fluid Initialization • Adding or Deleting RF Meters/Hoses • Adding or Deleting Operators Select INI CNF MET REP The parameters are: • System date and time are initially blank • System time is in military standard The INI menu can be accessed only when the Dispense Order (WO) list is empty.
Fluid Management System Standalone Keypad Tank Unit Tank No = To install a Tank: 1. Select Tank Unit Number. a. Enter a numeric value from 1 to 8 and press Enter. b. Pressing the Enter key with no entry advances to Fluids screens. Tank Unit Tank No 5 Tank Unit No 5 QUARTS Tank Stock Level No 5: 85604---- 2. Select Fluid Quantity or Remove a Tank. a. Use the Scroll key to select LITER, GALLONS, PINTS, QUARTS or REMOVE. (The REMOVE option deletes a tank from the system.) b.
Installation & Operation Manual Creating or Deleting an RF Meter/Hose (Meter and Hose are Synonymous) This set of screens allows a supervisor to create or delete RF Meters/Hoses from the keypad. • The RF Meter/Hose identification number is listed on the RF Meter/Hose under the battery pack or on an attached tag. Barcode of the Address Address • • • • • • The RF Meter/Hose Address identification number format is 10 decimal digits (X.XXX.XXX.XXX).
Fluid Management System Standalone Keypad Hose Address Already Used Hose Address Already Used This screen displays if another RF Meter/Hose already uses the same prefix and address. If this screen displays, check the RF Meters in the system to make sure duplicate RF Meters do not exist. Then check to see if this RF Meter/Hose has already been created in the system. The message displays for 3 seconds then returns to Create Hose screen.
Installation & Operation Manual CONFIGURATION (CNF) MENU The Configuration (CNF) Menu allows a supervisor to set up all parameters for the keypad operation. A supervisor is the only user with access to these screens. When everything is complete in the Configuration Menu, the supervisor should print the settings from the keypad and put them in a safe place. Refer to "Report (REP) Menu (External Printer)" on page 21 or "190 Menu (Internal Printer)" on page 21 for information on printing reports.
Fluid Management System Standalone Keypad Clearing Transactions from Keypad Memory • • Removes all transactions (Dispense Orders) previously recorded in memory. Clear transactions erases WO results data. Clear Transacts YES / NO Print WO? YES / NO Confirm Clear YES / NO Use the Scroll key to move the cursor to either YES or NO and press Enter. • If you select YES and the external printer is enabled (refer to "External Printer" on page 17 ), the display asks if you want to print the WO results.
Installation & Operation Manual Registration Information The Registration Information screen selects the option to collect registration information for each dispense order. The options are YES and NO (default). Regist. Info YES / NO 1. Use the Scroll key to move the cursor to either YES or NO. 2. Press Enter to advance to the Keypad Timeout screen. Keypad Timeout • • Timeout parameter corresponds to the time it takes to validate after all dispense order data has been entered.
Fluid Management System Standalone Keypad Barcode Scanner 1. Use the Scroll key to move the cursor to either YES or NO. Barcode Scanner YES / NO 2. Press Enter to accept the setting and advance to the next screen. • If you select YES, the display advances to the Scanner Lock screen. • If you select NO, the display advances to the Scanner screen. Hardware Requirements The barcode scanner must support an RS-232 output interface for use in the RF FMS.
Installation & Operation Manual Pin Number Prefix Code When PIN or ALL is selected for the Scanner Lock, you can choose an additional prefix character. The prefix character will not be displayed and cannot be entered on the keypad. PIN Encoded YES / NO Encode Prefix # 1. Use the Scroll key to move the cursor to either YES or NO. 2. Press Enter to move to Encode Prefix screen. 3. Press the Scroll key until the desired prefix displays.
Fluid Management System Standalone Keypad Display Fluid The Display Fluid screen selects the option to display the fluid selected. The options are YES (default) and NO. 1. Use the Scroll key to move the cursor to YES or NO. Display Fluid YES / NO 2. Press Enter to move back to the main Select screen. METER RESET (MET) MENU • • • Only the supervisor has access to MET. The supervisor may delete a dispense order in the keypad queue for a single hose or for all hoses in the system.
Installation & Operation Manual REPORTS When everything is complete in the Configuration Menu, the supervisor should print the settings from the keypad and put them in a safe place. You can print reports: • From an external printer via the Report menu. • From the internal printer via the 190 menu.
Fluid Management System Standalone Keypad Configuration Report Select report INI CNF COM WO 1. From the Select Report screen, use the Scroll key to move the cursor to CNF. 2. Press Enter to print the report. Communications Report Select report INI CNF COM WO 1. From the Select Report screen, use the Scroll key to move the cursor to COM. 2. Press Enter to print the report. Completed Work Order Report Select report INI CNF COM WO 1. Use the Scroll key to move the cursor to WO. 2.
Installation & Operation Manual RADIO (RAD) MENU The RAD menu screens are: • Address (ADR) – toggles the display between the Radio Address and the Radio Prefix screens. • Network (NWK) – allows you to select the Radio Network. • Power (PWR) – displays the radio’s transmit (Tx) output power. • Station (STA) – displays the Radio Network Status. Select INI CNF MET REP Select 190 RAD ... ... Select ADR NWK PWR STA To use the internal keypad printer: 1. Use the Scroll key to move the cursor to REP. 2.
Fluid Management System Standalone Keypad Radio Power Select ADR NWK PWR STA RADIO PWR LEVEL 20 dBm 1. Use the Scroll key to move the cursor to PWR. 2. Press Enter to display the Radio Power Level screen. 3. Press Enter to return to the selection screen. Radio Status The Radio Status options are: • NWK CONNECTED – The network is connected and operational. • SERIAL ERROR – There is a radio communication error on the serial bus between the keypad and the radio.
Installation & Operation Manual FLUID / TANK DEFINITIONS • • • Maximum of 8 Tanks and Fluids. The Tank capacity value is formatted xxxxx.xxx. Fluid name can be up to 16 alphanumeric characters.
Fluid Management System Standalone Keypad HOSE / METER DEFINITIONS • • • Maximum of 30 Hose / Meters. Hose Prefix data format is xx.xx.xx.xx (8 digits). Hose Address data format is x.xxx.xxx.xxx (10 digits). Hose / Meter Identification Hose Prefix xx.xx.xx.xx Hose Address x.xxx.xxx.
Installation & Operation Manual APPENDIX A – EPSON LX-300+II PRINTER OR COMPATIBLE An Epson LX-300+II printer, or compatible, must be used with the Standalone Keypad. Badger Meter takes no responsibility for, and does not support, any printer except an Epson LX-300+II.
Fluid Management System Standalone Keypad LX-300+II Printer Settings Page 28 August 2012
Installation & Operation Manual August 2012 Page 29
Fluid Management System Standalone Keypad Page 30 August 2012
Installation & Operation Manual August 2012 Page 31
Changing LX-300+II Settings 1. Go to Google.com. 2. In Google Search, type in LX-300+II. 3. Click on Epson LX-300+II, Overview - Technical Support - Epson America, Inc. 4. On the screen LX-300II Impact Printer, click on Documents & Manuals. 5. On the next screen click on Product information Guide. 6. Go to page 14 (Default Settings). 7. On the right side of the page is a segment titled "Changing Default Settings". Follow the instructions to change settings.