User's Manual

Page 46
1-12
ORION® Automated Meter Reading System for Trimble® Ranger™
1. To obtain a reading for a specic endpoint, tap the
Single S/N tab as shown in Figure 52.
2. Key the ORION serial number in the S/N eld, then
tap Start Reading on the lower right of the screen.
Result: The screen displays the reading for the serial
number entered.
3. Tap Stop Reading on the lower right of the screen
to stop the Quick Read.
Figure 52: Single Endpoint Reading
Prole
The Profile tab displays an historical record for the ME/SE endpoint. A water endpoint will store 90 days of hourly readings.
The number of days of storage for more frequent intervals is proportionally decreased (22 days for 15 minute intervals and 7
days of five minute intervals).
This data is stored as blocks of 24 readings. In handheld and mobile applications, customers can request all 90 days or certain
blocks (days) of data.
S/N Displays the serial number of the ORION ME endpoint.
1st Dt/Tm Displays the first date of the selected profile. For example, if you request 7 in the Days field, the
date displayed is 7 days prior to the current date..
Days Select the number of days of data for the profile. Available choices: 1, 7, 14, 30, 60, ALL (90)
Interval Displays the interval for the profile calculation. For example, 60 = hourly reads.
Quantity Display the number of hourly reads chosen/heard.
Consumption The dierence between the start and end reads in the prole requested.
Status(es) Displays any potential issues that require attention. Example: tamper, no usage, etc.
Save Save the data to send back with the route information.
1. Tap the Prole tab.
To use IR, select IR from the drop down and use the IR cable to read the SN. Then tap Prime Read.
or
To use RF, select RF from the drop down and enter the serial number using the keypad. Then tap Read Data.
Result: All profile data for the endpoint, up to 90 days of hourly reads, is collected.