Recordall® 308 Summator/Splitter REG-UM-01013-EN-08 (August 2014) Installation Manual
Recordall®, 308 Summator/Splitter Page 2 August 2014
Installation Manual DESCRIPTION Application/Operation The latest version of the Summator/Splitter model is designed to work with the Badger Meter Recordall® Compound Series meter. In all cases, connection takes place between the various components by the use of the Badger Meter 308 in-line connector. The 308 in-line connector provides flexibility in system selection, can be operated in a submersible environment and is tamper proof.
Recordall®, 308 Summator/Splitter Summator/Splitter with 308 Connectors 6’ Low Flow Cable Double Register Input Summator/Splitter 9” Cable with 308 Connector for ORION/GALAXY or 308 Connector Harness RTR 6’ High Flow Cable Single Register Input Summator/Splitter 6’ Input Cable 9” Cable with 308 Connector for ORION/GALAXY or 308 Connector Harness 9” Cable with 308 Connector for ORION/GALAXY or 308 Connector Harness RTR Summator/Splitter with Itron In-line Connectors 6’ Low Flow Cable Double Regis
Installation Manual CONNECTING THE INPUT 308 IN-LINE CONNECTOR TO AN RTR To ensure the Badger Meter 308 in-line connector assembly is properly installed, follow these installation steps : NNOTE: When installing a Summator product to a compound or fire series assembly, make sure the proper 308 in-line connector is assembled to the appropriate high or low side RTR. The 308 in-line connector cables are labeled with either a "HIGH FLOW" or "LOW FLOW" tag to assist with proper installation.
Recordall®, 308 Summator/Splitter 2. To prevent the connectors from being installed incorrectly, each connector is keyed so the two halves are correctly aligned. Align the male and female connector keys and gently push both together. While pushing the connector assemblies together, two audible clicks indicate complete connection. Male connector Female connector Key Key Figure 2: Male and female connectors and keys 3. Position the anti-tamper collar (66233-004) over the connector and close it.
Installation Manual CONNECTING THE OUTPUT 308 IN-LINE CONNECTOR TO AN ENDPOINT Connector cables are labeled "OR/GA" to indicate compatibility with an ORION or GALAXY endpoint, or "ITRON" for an Itron in-line connector. To connect an endpoint to the appropriate cable, see "Connecting the Input 308 In-line Connector to an RTR" on page 5.
Making Water Visible® MAKING WATER VISIBLE, RECORDALL, ORION, and GALAXY are registered trademarks of Badger Meter, Inc. Other trademarks appearing in this document are the property of their respective entities. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding contractual obligation exists. © 2014 Badger Meter, Inc. All rights reserved. www.badgermeter.