Model RF-OMS Radio Frequency Oil Management System Installation & Operation Manual IMPORTANT !!!! This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Specific keypad/software set-up instructions are contained in the keypad packaging. IOM-085-01 BadgerMeter,Inc. ® Part No.
12.Do NOT dispense valves towards any person or any part of the body. 13.Do NOT place hands or fingers over the end of or into the dispense valve. 14.Comply with all local, state, and federal fire, electrical, and safety regulations 15. Use of this product in a manner other than specified in this manual may result in impaired operation or damage to equipment. TABLE OF CONTENTS Definitions ...................................................................... 2 Installation .................................
be programmed to the meters that you want it to communicate with. To begin the programming, reference the detailed Instruction Manual on Page 5. is unable to communicate with the keypad. All dispenses in this mode are recorded to memory and, in total, are communicated to the keypad once communications are reestablished. Inventory levels and consumption data are updated when communications are restored. Menu Configuration. Software included in the RF-OMS allows for tracking of all fluids under its control.
5. dispense order is received by the meter. Slowly open the dispense valve and allow enough oil to pass through to ensure that the system is clean. Close the valve and repeat for all dispense positions. 6. 7. QT . Note: If the system has multiple dispense positions, begin at the position farthest from the pump, and move towards the pump. Relieve the Pressure (see Relieve the System Pressure, above).
2. Pull the trigger to begin the flow. 3. When the desired amount has been pumped, release the trigger to stop the flow. Press Do NOT press to before topping off. The meter will begin a new batch. reset counter display to zero. Normal Operating Mode Functions Programming the Preset Batch Function when RF Communications are Unavailable Total This option allows users to see the accumulated total as well as the resettable total. 1. To enter the batch-programming mode, press the button.
2. Second warning: The AUTO function will shut off and the auto icon will disappear. This means the battery power is too low to run the auto function. The meter can still run in manual mode. Programming the Units This meter comes with the option to choose 4 different units of measure. Unless otherwise specified at the time of the order, each meter is programmed in liters for use with motor oil. The ‘L' will be flashing on initial start-up. 1. Toggle the four options (‘L’, ‘QT’, ‘GAL’, ‘PT’) by 3.
Recalibrating the Meter The Scale factor is used to adjust the accuracy of the meter. The scale factor will be set at the factory for oil. The primary use for the recalibration function is if the user wants to batch fluids with a viscosity other than 10W oil. If the fluid has a lower viscosity, more fluid can slip past the gears without being detected.
11.00" 3.50" 6.00" SPECIFICATIONS English Metric Maximum Flow * 8 gpm 30 lpm Minimum Flow * 0.25 gpm 1 lpm Operating Pressure (Maximum) 1000 psi 67 bar Operating Pressure (Minimum) 5 psi .35 bar Operating Temperature (Maximum) 120° F 50° C Operating Temperature (Minimum) 20° F - 5° C Accuracy +/- 0.5% +/- 0.
1 2 ITEM # 1 2 PART DESCRIPTION PART NUMBER Top Case with Screws Keypad 64103-006 63802-002 NOTE: For service required on parts not listed above, please contact Badger Meter's authorized service center in Milwaukee.
1 2 ITEM # 1 2 PART DESCRIPTION Battery Door with Screws Bottom Case with Screws PART NUMBER 64103-004 64103-003 NOTE: For service required on parts not listed above, please contact Badger Meter's authorized service center in Milwaukee.
2 1 3 ITEM # 1 2 3 PART DESCRIPTION PART NUMBER Valve Assembly Gear Service Kit with O-Ring Trigger Assembly 64103-001 62896-001 64103-005 NOTE: For service required on parts not listed above, please contact Badger Meter's authorized service center in Milwaukee.
Please see our website at Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding bid obligation exists. www.badgermeter.com BadgerMeter,Inc. for specific contacts. Copyright © Badger Meter, Inc. 2002. All rights reserved. ® P.O. Box 245036, Milwaukee, WI 53224-9536 Telephone: (414) 355-0400 / (877) 243-1010 Fax: (414) 355-7499 / (866) 613-9305 www.badgermeter.