Instruction Manual
Change Batch Preset Value
The batch preset value appears on line 2 of display screen 1. It will be a six, seven, or eight digit number. Only the six most 
significant digits of this number are editable. Any remaining zeroes in the least significant place or places will always remain 
at zero. Press the Edit key. One of the digits on line 2 will be flashing. If any zeroes are to the right of the flashing digit, they 
cannot be changed, and the preset must be entered with those in mind. Use the 0-9 keys to edit the preset value, and then 
press the Enter key to store the new value.
Examples:
The present batch preset value appears on line 2 as 000750 gallons (six digits). Change this value to 780 gallons.
When the edit key is pressed the sixth digit from the left (0) will flash. Press keys 7, 8, and 0, and line 2 will read 000780, with 
the last digit still flashing. Press the Enter key and the new number (000780) will be stored and the flashing will stop.
The present batch preset value appears on line 2 as 0000750 gallons (seven digits).
Change this value to 780 gallons.
When the edit key is pressed, the sixth digit from the left (5) will flash. Press keys 7 and 8, and the line 2 number will read 
0000780, with the “8” flashing. Press the Enter key and the new number 0000780 will be stored and the flashing will stop.
Change Timeout Period
Press the View/Enter key to put screen 2 on the display. Screen 2 will read:
Timeout 
0010 Sec.,(or some other value.)
Press the Edit key. The least significant digit (in this case, a zero) will flash. Use the 0-9 keys to edit the timeout value on line 2. 
Press the Enter key to store the new value.
Change Running Count Value
The running count is displayed on the top line of screen 1. It is a six-digit count, which may have one or two zeroes attached 
to the right side. Any leading zeroes on the left side are deleted. It may be necessary for the operator to change the present 
value. First decide what new value the count should be. Then, with screen 1 being displayed, press the Reset key. The display 
will read:
Reset to 
0000010, (or some other value.)
Press the Edit key. The sixth digit from the left (in this case a “1”) will flash. Use the 0-9 keys to edit the value, and then press 
Enter to store the value. To complete the process, press the Reset key again. The display will return to screen 1, and the 
running count will go to the new value. If the process is not completed in 20 seconds, the display will go back to screen 
1 automatically.
STARTUP CHECKLIST
1.  If the bottom line of display reads “Enter program Mode,” press the Run/Program key. Bottom line should read 
"Start Stop."
2.  Access the programming screen and set up the mode, lockout type, and pulse weight.
3.  Set running batch count to first batch size.
4.  Enter batch preset value.
User Manual