Manual
TRACE
®
 is a registered trademark of American Meter Company. Badger
®
, Recordall
®
, ORION
®
, 
and RTR
®
 are registered trademarks of Badger Meter, Inc. Itron
®
 and ERT
®
 are registered 
trademarks of Itron, Inc. TORX
®
 is a Registered trademark of Camcar, Division of Textron, Inc. 
Hexagram
®
 is a trademark of Hexagram, Inc. RAMAR
®
 is a trademark of RAMAR Technology.
Other trademarks appearing in this document are the property of their respective entities.
© 2012 Badger Meter, Inc. All rights reserved. 
Due to continuous research, product improvements and 
enhancements, Badger Meter reserves the right to change 
product or system specications without notice, except to the 
extent an outstanding contractual obligation exists.
Badger Meter | P.O. Box 245036, Milwaukee, Wisconsin 53224-9536 
800-876-3837 | infocentral@badgermeter.com | www.badgermeter.com
PIT INSTALLATIONS
Insert the entire splice assembly into the lled splice tube P/N 62085-
001 as indicated in Figure 6. Close the cover with leads exiting alternate 
sides as indicated in the drawing.
TESTING
After connections are complete, test the entire installation including the 
RTR, wiring, and remote or pit module for proper operation in accordance 
with the instructions supplied with the module.
Install the RTR on the water meter and secure it using the TORX
®
 screw 
provided.
TROUBLE SHOOTING
An analog ohm meter will show an "open" reading when connected 
across the OUTPUT leads of the RTR. When operating the RTR, the 
ohm meter should show a momentary deection toward zero when the 
RTR sends a signal.
Figure 6. Splice Enclosure Assembly
RTR
®
 with three wires (brown cable)
For connection to ORION
®
 Transmitter, Hexagram
®
 Star Module or RA-
MAR
®
 V4 Transpondit, verify the RTR has a brown cable and contains 
a label with either an 'HE' for connectivity to Hexagram or an 'RA' for 
connectivity to RAMAR. Using the chart below, connect the RTR con-
ductors to the AMR module conductors using insulation displacement 
gel-lled splices, P/N 59761-001 provided in the installation kit. Crimp 
the cables completely using a parallel jaw crimper, P/N 59983-001.
For connection to an Itron
®
 remote ERT
®
, verify that the RTR has a brown 
cable and contains an 'IT' on the label. For more information on the 
installation instructions for the Itron remote ERT, please refer to Itron's 
Installation Remote ERT Modules 40W-1 and 50W-1.
Figure 4. 3 Conductor RTR Splice Installation Diagram
  Hexagram Itron 
RTR  ORION  Ramar V4  Pit/Remote  Remote
Red Red Wire #2 Red  Red
Black Black Wire #3 Black  Black
Green Green Wire #1 White  Green
If the wire is cut or broken and requires a eld splice after initial 
installation, connect like colors to maintain proper installation.
Place the two plastic cable ties P/N 34776-001 on wires and tighten 
securely for strain relief. Remove excess cable tie with wire cutting 
device.
CABLE TIES
(Remove Excess)
GEL-SPLICE
Figure 5. Splice Installation Diagram